![Avaya S8700 Series Скачать руководство пользователя страница 2041](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022041.webp)
PPP-PT (Control LAN Packet/Port)
Issue 1 May 2002
8-1319
555-233-143
SCOTCH Synchronous Loop-Around Test (#1275)
NOTE:
This test is destructive.
This test verifies the circuit in the datapath of a ppp call. This test fails if the data
transmitted on the port does not match the data received in the loop-around
mode. Failure of this test indicates a port hardware fault on the circuit pack.
This test aborts if calls are using the port, or if the PPP link associated with the
port is connected. To avoid this, first enter busyout data-module extension, or
busyout port UUCSSpp, or busyout link link#, which will cause every call and
link using the port to be torn down.
2000
ABORT
Did not receive circuit pack test response within the allowable time period.
1. If this problem persists, reset the circuit pack (busyout board UUCSS,
reset board UUCSS, and release board UUCSS).
2. If the problem persists, replace the circuit pack.
2012
ABORT
Internal system error.
1. Retry the command at 1-minute intervals up to 3 times.
2. Escalate if the problem persists.
2100
ABORT
Could not allocate the necessary system resources to run test.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate if the problem persists.
FAIL
Received tones do not match transmitted tones.
1. Retry command at 1-minute intervals up to 3 times.
2. If the problem persists, see
,
and Tone Receiver repair procedures.
3. If the problem persists, reset the board (busyout board UUCSS, reset
board UUCSS, and release board UUCSS). Repeat the test.
4. If the problem persists, replace the circuit pack.
PASS
Port connections across the TDM bus function properly.
Table 8-529.
Test #1285 TDM Loop-Around Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...