Maintenance-Object Repair Procedures
555-233-143
8-536
Issue 1 May 2002
Digital Terminal Audits Test (#17)
This is a series of tests that are classified as audits. The media server sends
messages to the softphone application or IP phone to perform the following tests.
These audits run only if the station is in-service.
■
Switchhook Inquiry test
—
This updates the media server’s records
according to the softphone switch-hook state.
■
Ringer Update test
—
This updates the softphone’s ringer state according
to the media server’s records.
■
ID Request
—
This queries the station for its status.
Table 8-216.
Test #16 DIG-LINE Station Lamp Updates Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
1
ABORT
This port could have been busied out by system technician.
1. Look in the Error Log for Error Type 18 (port busied out) for this port. If this
error type is present, then release the port via the release station
extension command and run the test again.
2. Make sure that the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
3
ABORT
Station could be in ready-for-service or out-of-service state.
1. Use status station command to verify state of station.
2. Make sure the terminal is connected.
3. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port could be
busy with a valid call.
1. Use display port UUCSSpp to determine the station extension of the port.
Use status station to determine the service state of the port. If the port is
in use, wait until it is idle before testing.
1. If the port status is idle, then retry the command at 1-minute intervals up to
5 times.
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The message to light every station lamp was successfully sent to the port.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...