h. Error Type 1793 – This error occurs when the BRI Port Local TDM Loop
Around test (#619) fails. Run the long test sequence, and pay particular
attention to the results of Test #619.
There are no Test to Clear Values for the following error types. The error
types are simply provided as additional data that may prove useful while
troubleshooting.
i. Error Type 3841 – This error occurs when a Layer 1 Transmission error is
detected for the port. Run the long test sequence, and pay particular
attention to the results of the Layer 1 Transmission Error Counter test
(#624).
j. Error Type 3842 – A BRI port supports up to three Terminal Endpoint
Identifiers (TEIs). This error occurs when the switch receives a request for
a fourth TEI on a port. Check the number of endpoints administered for
this port.
k. Error Type 3843 – This error occurs when an SPID initialization request is
made from an endpoint and the switch determines that the SPID value is
invalid or is a duplicate of another SPID that is already initialized at Layer 3
on the port. Check the administration of the endpoints.
l. Error Type 3844 – This error occurs when the circuit pack detects an
overflow of its receive buffers. Run the long test sequence, and pay
particular attention to the results of the Receive FIFO (First In First Out)
Overflow Error Counter test (#625).
m. Error Type 3845 – This error occurs when the BRI Port Local LAN Loop
Around test (#618) fails. Run the long test sequence, and pay particular
attention to the results of Test #618.
n. Error Type 3846 – This error most likely occurs when the Terminal
Endpoint Identifier (TEI) administered for the ASAI or Avaya endpoint does
not match the TEI administered in the ASAI or Avaya adjunct. Check the
switch administration of the TEI against that of the adjunct and make sure
that both are using the same TEI.
o. Error Type 3847 – Indicates that sets on the port do not support layer-3
initialization. Consult the Service Set documentation.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...