ATM PNC-DUP (ATM PNC Duplication)
Issue 1 May 2002
8-247
555-233-143
Resolving Poor State of Health
When both PNCs do not have an all-zero SOH (perfect health), use the following
steps to identify and repair the problem.
1. Look for PNC component alarms (major or minor) for the PNC side without
an all-zero SOH. The standby PNC should be repaired first.
2. Busy-out the standby PNC.
3. Follow the appropriate diagnostic and repair procedures for the alarmed
PNC components just as with a simplex PNC. Both the alarm and error
logs should be examined to isolate the fault.
4. Verify that the related PNC’s SOH is restored to all zeros.
5. Release the standby PNC.
Refresh and Unrefresh of the Standby PNC
In a fully-functional PNC with healthy standby and active sides, the standby PNC
has a complete set of call connections corresponding to those in the active PNC.
If, however, the standby PNC’s state of health degrades, a selective unrefresh of
those connections that utilize the faulted component(s) is performed. If the
standby PNC’s health improves, a selective refresh of connections on the affected
route is performed so that call setup is consistent between the active PNC and the
healthy parts of the standby PNC.
The
Standby Refreshed?
field on the status pnc form does not refer to the
selective type of refresh. It refers only to a global refresh that is performed when:
■
The system is initialized and PNC duplication is enabled.
■
There has been a spontaneous PNC interchange.
■
The standby PNC has been released from busy-out.
■
A system reset of level 2 or higher has taken place.
The
Refreshed
field may display yes when in fact the standby is partially
unrefreshed. An interchange into an incompletely refreshed standby results in
dropped calls. This can happen when a more severe fault occurs on the active
PNC or when reset pnc interchange is used with the override option.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...