ADX8D-PT (AUDIX Digital Port)
Issue 1 May 2002
8-19
555-233-143
NO-OP Tests
The maintenance strategy for EMBEDDED AUDIX emulates the one for
DIG-LINE. The following tests apply only to DIG-LINE and not to EMBEDDED
AUDIX. These are referred to as NO-OP tests, and they always return PASS.
■
Electronic Power Feed test (#11)
■
Station Lamp Updates test (#16)
■
Station (Digital) Audits test (#17)
NPE Crosstalk Test (#9)
This test verifies that this port’s NPE channel talks on the selected time slot and
that it never crosses over to time slots reserved for other connections. An NPE
that is not working correctly may cause 1-way and noisy connections. This test is
part of a port’s long test sequence, and it executes in about 20 to 30 seconds.
Crosstalk testing is performed on both the primary (for voice) and the secondary
(for data) information channel associated with each EMBEDDED AUDIX port. If
this test fails on either channel, the voice port is taken out of service.
Table 8-7.
Test #9 NPE Crosstalk Test
Error
Code
Test
Result
Description / Recommendation
1
ABORT
During testing of the primary information channel, system resources may not
have been available. Also, the port may have been busy during the test.
1. Check the port status.
2. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the service state indicates that the port is active,
wait until it is idle.
3. Retry the command at 1-minute intervals up to 5 times.
2
ABORT
System resources may not have been available, or the port may have been
busy during the test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
active.
1. Use the display port UUCSSpp command to determine the voice port
extension of the port. Use the status station command to determine the
service state of the port. If the service state indicates that the port is active,
wait until it is idle before retesting.
2. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...