Maintenance-Object Repair Procedures
555-233-143
8-1468
Issue 1 May 2002
138
FAIL
The physical neighbor location does not match administered neighbor location.
The carrier and slot of the administered neighbor do not match the carrier and
slot of the physical neighbor. Enter list fiber-link, and verify that the fiber-optic
cable and metallic cable connections are installed as administered. If the
problem does not seem to be caused by a physical connection problem or an
administration problem, replace the neighbor circuit pack. It is possible for the
neighbor circuit pack to have a hardware problem that causes it to report a
wrong angel address (physical carrier/slot address) to software.
139
FAIL
The SNI is administered to be connected to a DS1C but is not physically
connected to a DS1C. If a DS1C is not supposed to be connected to this SNI,
change administration to remove the DS1 converter complex from the fiber link
associated with this SNI by:
1. Determine which fiber that this SNI is an endpoint of by checking list
fiber-link.
2. Remove this fiber with the remove fiber-link command.
3. Add the fiber back via add fiber-link, and do not administer the DS1
converter complex at this time.
140
FAIL
The SNI is physically connected to a DS1C but is not administered to be
connected to a DS1C.
Either add the DS1 converter complex to the fiber that this SNI is associated
with by:
1. Determine which fiber that this SNI is an endpoint of by checking list
fiber-link.
2. Remove this fiber with the remove fiber-link command.
3. Add the fiber back via add fiber-link, and at this time also administer the
DS1 converter complex.
Or:
1. Remove the DS1C connection, and connect the SNI directly to its
administered fiber endpoint.
2. Verify that the fiber-optic and metallic cable connections are installed as
administered by entering list fiber-link.
PASS
The administered data and the circuit packs the SNI can communicate with
match.
Table 8-579.
TEST #759 Configuration Audit —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...