Maintenance-Object Repair Procedures
555-233-143
8-938
Issue 1 May 2002
NIC Query Test (#1383)
This test is nondestructive.
This test passes if the Ethernet port is connected, and you can talk on the
network. Otherwise, it fails with no fail code or AUX data.
Ping Test (#1379)
This test is a non-destructive test.
This test verifies that the MedPro circuit pack can communicate to other nodes on
the LAN.
Table 8-364.
Test #1383 NIC Query Test
Error
Code
Test
Result
Description / Recommendation
None
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
1015
ABORT
Port is not out of service.
1. Enter busyout board UUCSS to busyout the circuit pack.
2. Execute the command again.
2100
ABORT
System resources required for this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
FAIL
The Ethernet port is not connected, and you cannot talk on the network.
PASS
The Ethernet port is connected, and you can talk on the network.
0
NO
BOARD
The test could not relate the internal ID to the port (no board). This could be
due to incorrect translations, no board is inserted, an incorrect board is
inserted, or an insane board is inserted.
1. Ensure that the board’s translations are correct.
2. If the board is not correctly administered, administer the MedPro interface.
If correctly administered, check the error log to determine whether the
board is hyperactive. If so, the board was shut down. Reseat the board to
re-initialize it.
3. If the board is correctly inserted and administered, issue the busyout
board UUCSS command.
4. Issue the reset board UUCSS command.
5. Issue the release board UUCSS command.
6. Issue the test board UUCSS long command.
This should re-establish the linkage between the internal ID and the port.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...