Automatic Transmission Measurement System
Issue 1 May 2002
5-39
555-233-143
Output Fields
ATMS Reports (List Testcall Command)
The list testcalls command produces detailed and summary reports of
measurements made by the ATMS. Measurement reports contain data on trunk
signal loss, noise, singing return loss, and echo return loss, and are used to
determine the quality of trunk lines. The system maintains a database with the
results of the last test for each trunk. System resets clear all transmission test
data, and ATMS measurements are not backed up by the MSS.
ATMS parameters are administered on the Trunk Group form. These include
thresholds for marginal and unacceptable performance. On the screen display,
measurements that exceed the marginal threshold are highlighted.
Measurements that are exceed the unacceptable level appear flashing, indicating
unusable trunks. Trunk groups can be administered to log errors and alarms, and
to busy out the failed trunk in response to such results.
Port
The physical location of the port supporting the trunk being
tested. The format is UUCSSpp where UU is the cabinet
number, C is the carrier letter, SS is the circuit pack slot, and
pp is the port circuit number.
Maintenance
Name
The name of the maintenance object tested, TIE-TRK or
CO-TRK.
Alt. Name
The trunk-group number and member number of the trunk
being tested.
Test Number
ATMS tests are numbered 844 through 848.
Result
■
If the test call successfully completes, and if every trunk
tests within administered thresholds for marginal and
unacceptable performance, then a PASS result is returned.
■
If measurements fall outside the thresholds, the test fails.
The trunks group can be administered to log errors and
alarms, and to busy out the failed trunk.
■
If the test call cannot be completed, an ABORT is returned.
Error Code
This numerical code indicates the reason for a failure or abort.
The codes are explained in the CO-TRK and TIE-TRK sections
of
‘‘ABRI-PORT (ASAI ISDN-BRI Port)’’ on page 8-3
.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...