M/T-ANL (Maintenance/Test Analog Port)
Issue 1 May 2002
8-1147
555-233-143
M/T-ANL (Maintenance/Test Analog
Port)
The Maintenance/Test analog port is port number 1 on the TN771D Maintenance/
Test circuit pack. This port is used by the Automatic Transmission Measurement
System (ATMS) as an Originating Test Line (OTL) or Terminating Test Line (TTL)
for test calls over analog trunks. For more details, see “Automatic Trunk
Transmission System” in
Chapter 5, ‘‘Additional Maintenance Procedures’’
shows a typical ATMS configuration.
M/T-ANL maintenance ensures that the analog trunk’s testing function is
operating correctly. Although an M/T-ANL alarm can reduce service, it will not
block service. To accurately measure the performance and health of analog
trunks, replace an alarmed TN771D when a new circuit pack is available.
Figure 8-66.
ATMS Tie Trunk Test Call
MO’s Name (in
Alarm Log)
Alarm
Level
Initial SAT Command to
Run
1
1.
UU is the universal cabinet number (1–64 for ATM PNC, 1–44 for CSS PNC). C is the carrier designation (A,
B, C, D, or E). SS is the number of the slot where the circuit pack resides (01–21). pp is the 2-digit port number
(01, 02,...).
Full Name of MO
M/T-ANL
Minor
test port UUCSSpp l
Maintenance/Test analog port
M/T-ANL
Warning
release port UUCSSpp
Maintenance/Test analog port
Tie
Trunk
Facilities
Originating
Test Line
(OTL)
TN771
TDM Bus
Terminating
Test Line
(TTL)
TN771
TDM Bus
PBX originating
the test call
PBX terminating
the test call
Tie Trunk
Circuit Pack
Tie Trunk
Circuit Pack
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...