![Avaya S8700 Series Скачать руководство пользователя страница 1899](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021899.webp)
M/T-PKT (Maintenance/Test Packet Bus Port)
Issue 1 May 2002
8-1177
555-233-143
If the system has been in a stable state for more than 15 minutes, try the
following procedure:
1. Reset the Maintenance/Test circuit pack from the G3-MT as follows:
■
Enter the busyout board UUCSS command.
■
Enter the reset board UUCSS command.
■
Enter the release board UUCSS command.
2. Wait 15 minutes.
3. If the error recurs, replace the Maintenance/Test circuit pack.
When this alarm is active, the amber LED will be in one of three states:
■
An unlit amber LED indicates no activity on the Maintenance/Test
circuit pack. You can replace the Maintenance/Test circuit pack.
■
If there is an indication of an uncorrectable fault on the packet bus,
the amber LED will be blinking at a rate of 1 Hz. It is OK to replace
the Maintenance/Test circuit pack. Ignore the packet-bus error
indication, since the Maintenance/Test circuit pack has been
determined to be defective.
■
If there is other activity on the Maintenance/Test circuit pack (i.e.,
ISDN test call), or if there is an indication of a correctable fault on
the packet bus, the amber LED will be on steady. If there is an ISDN
test call in progress, it must be halted via the clear isdn-testcall
grp/member command prior to replacing the circuit pack. Ignore
the packet-bus error indication, since the Maintenance/Test circuit
pack has been determined to be defective.
d. This error indicates a failure of the Packet Bus Port Health Inquiry test.
Either the packet-bus port has reported a self-test failure, or the Avaya
MultiVantage™ software can communicate with the Maintenance/Test
circuit pack but not with the Maintenance/Test circuit pack packet-bus port.
Refer to the description of the Packet Bus Port Health Inquiry test, and
follow the instructions indicated for the failure code that matches the
Aux
Data
field.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...