EXP-INTF (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-813
555-233-143
1141
ABORT
The Packet Interface circuit pack is out of service.
1. See
‘‘PKT-INT (Packet Interface)’’
for the recommended repair procedure.
1144
ABORT
The PN’s packet bus has a major alarm against it. This test needs to use the
alarmed PN’s packet bus.
1. Enter display alarms and resolve any PKT-BUS alarms.
2. Retry the command.
1394
ABORT
The EI circuit pack is out of service and the test cannot be run. This condition is
due to a change in the EI circuit pack’s ability to communicate with the EI or SNI
circuit pack on the other end of the fiber.
1. Run Test #237 and check the Error Log for EXP-INTF Error Type 1281. If
Error Type 1281 is present or if Test #237 does not pass, see the repair
procedures for Test #237, in
.
2. If Test #237 passes, rest the EI pack. Note that this will not be destructive to
the port network where EI circuit pack resides because it will not be serving
as the expansion Archangel if it is not in service.
3. Repeat this test.
1395
ABORT
This test cannot be run on an EI circuit pack if it is part of the B-side Port
Network Connectivity and duplicated Port Network Connectivity is not enabled.
1. If this test needs to run on this EI circuit pack, enable Port Network
Connectivity with the change system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the set
PNC lock command.
3. Repeat this test.
Table 8-310.
Test #589 Expansion Interface Packet Interface Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...