Table 8-505.
Test #572 Maintenance/Test Circuit Pack Query Test
Error
Code
Test
Result
Description / Recommendation
1006
ABORT
The packet bus port of the Maintenance/Test circuit pack is out of service.
1. Determine whether the port is busied out. If so, release it with the release
port UUCSS04 command. Then retry the test command.
2. If there are alarms active against the packet bus port (MT-PKT), see
‘‘M/T-PKT (Maintenance/Test Packet Bus Port)’’
to resolve them. Then
retry the test command.
1142
ABORT
No Maintenance/Test circuit pack packet bus port is in service in this PN.
1. If this PN is required by configuration guidelines to have a
Maintenance/Test circuit pack:
a. the Maintenance/Test circuit pack for this PN has failed, and should be
replaced,
b. the Maintenance/Test circuit pack has been busied out, and should be
released, or
c. there is no Maintenance/Test circuit pack in thisPN, and one must be
installed.
2. In an PN of a system without PNC duplication, the Maintenance/Test
packet bus Port is not required and may not be present. If it is present, and
is busied out, or has failed, release or replace the circuit pack. If there is
no Maintenance/Test circuit pack, ignore the results of this test for this PN.
2000
ABORT
The test timed-out while waiting for an uplink CCMS response from the
Maintenance/Test packet bus port.
1. Re-enter the command at 1-minute intervals up to 5 times.
2. If the test continues to abort, check for problems with the Maintenance/Test
packet bus port (look for M/T-PKT in the Error and Alarm Logs).
2059
ABORT
The Maintenance/Test packet bus port has reported a hardware failure.
1. See
‘‘M/T-PKT (Maintenance/Test Packet Bus Port)’’
to correct the
problem.
2. Re-enter the test command.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...