![Avaya S8700 Series Скачать руководство пользователя страница 72](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102072.webp)
Initialization and Recovery
555-233-143
3-10
Issue 1 May 2002
Reset Level 2 (Cold-2 Restart)
Duration
Up to 3.75 minutes
Causes
reset system 2 command from MultiVantage (SAT/ASA) command line
Escalation from SAT’s reset level 1
An attempted SAT’s reset level 1 during a PNC interchange
Spontaneous interchange into an unrefreshed standby server
Effects
Every system and application link is dropped.
Every call is dropped.
Every administrative session is dropped.
Every system link is dropped and re-established.
Every application link is dropped and re-established.
Non-translation feature data, such as Automatic Wakeup calls, are lost and
must be re-entered.
Translation data is preserved in memory. If a “save trans” operation is in
progress, a SAT-requested cold-2 restart would be aborted. A
software-requested cold-2 restart would result in an unsuccessful “save
trans” operation and possibly corrupt translations.
Every G3-MT login, including remote access and system port logins, is
dropped.
Initialization firmware runs diagnostics and displays results on the G3-MT
screen.
Server memory shadowing is turned off, leaving the standby server
unavailable for service for up to several minutes.
Every hardware component, except activeTN2312 IPSI in any PN, active EI
in a non-IPSI connected PN, SNIs, SNCs, and DS1 clocks.
For a critical-reliability system (duplicated PNC), a global refresh of the
standby PNC is performed after the reset.
Every busied-out MO is released and can be rebusied.
Circuit packs are reinitialized. (Translations are verified by comparison to
physical boards’ locations.)
Error and alarm logs are preserved, and every MultiVantage alarm is
resolved.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...