ATM Board DSP Test (#1293)
Nondestructive
There are three kinds of digital signal processors (DSPs): talkers, listeners, and
echo cancelers.Talkers put data on the TDM bus, listeners take data off the TDM
bus, and echo cancelers filter out echoes of the main transmission. Firmware
allocates DSPs in sets of three (one of each type), up to a maximum of 8 sets.
This has three parts, one for each type of DSP. If the test fails for every DSP, a
MAJOR alarm is raised. If the test fails for one or more DSPs, a MINOR alarm is
raised. If a DSP is busy, the test passes for that DSP. The test aborts if system
resources are not available. Each part of the test returns the number of DSPs that
passed or failed. This test run during initialization, error analysis testing, periodic,
scheduled, and craft short and long testing.
Table 8-131.
ATM Board DSP Test (#1293)
Error
Code
Test
Result
Description / Recommendation
1002
ABORT
Could not allocate time slots. Traffic could be heavy or time slots could be
out-of-service.
1. Run display errors, and follow associated repair procedures for
TDM-BUS.
2. Retry the command up to 3 times at 1-minute intervals.
1003
ABORT
Could not allocate a Tone Detector. Too few Tone Detectors present or Tone
Detectors out-of-service.
1. Run display errors, and follow the repair procedures associated with any
TTR-LEV (TTR Level) errors that appear.
2. Verify that there is at least one Tone Detector in the EPN that holds the
ATM-TRK circuit pack.
3. Resolve any TONE-PT (Tone Generator) errors listed in the Error Log.
4. Retry the command up to 3 times at 1-minute intervals.
1962
ABORT
Every DSPs is busy. This is a very unlikely event.
1. Retry the command up to 3 times at 1-minute intervals.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...