CO-TRK (Analog CO Trunk)
Issue 1 May 2002
8-463
555-233-143
CO Demand Diagnostic Test (#3)
For ground start trunks, port circuit pack relays are operated and checks are
made to see if the port can detect and apply ground on the Tip lead. This test also
verifies that there is no external ground on the Ring lead. In the absence of other
failures, the circuit pack should be replaced only if this test fails with the CO line
disconnected.
For the TN2147, this test also checks the on-board programmable transmission
circuits that allow the circuit pack to support transmission characteristics of
several different countries.
Table 8-186.
Test #3 CO Demand Diagnostic Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Could not allocate system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1000
ABORT
System resources required to run this test are not available. The port may be
busy with a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is active, then it is unavailable for certain tests. Wait until the port
is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1004
ABORT
The port was seized by a user for a valid call.
1. Use the display port UUCSSpp command to determine the trunk
group/member number of the port. Use the status trunk command to
determine the service state of the port. If the service state indicates that
the port is active, then it is unavailable for certain tests. Wait until the port
is idle before retesting.
2. If the port status is idle, retry the command at 1-minute intervals up to 5
times.
1005
ABORT
Test inapplicable to present configuration. This is a normal condition.
1018
ABORT
Test has been disabled via administration.
1. For this test to run, the
Maintenance Tests?
field on the trunk group
form must be set to
n
. The form is accessed with the change trunk-group
grp# command.
2000
ABORT
Response to the test was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...