Maintenance-Object Repair Procedures
555-233-143
8-638
Issue 1 May 2002
Table 8-256.
Test #1211 CSU Repeater Loop-Back Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry test ds1-loop UUCSS ds1/csu-loopback-tests at 1-minute
intervals up to 5 times.
1005
ABORT
CSU Repeater Loopback test cannot be executed in the current configuration.
To run this test, the
Near-End CSU Type
field on the DS1circuit pack
administration form must be set to integrated and the
Bit Rate
field on the
DS1 circuit pack administration form must be set to “1.544” (24-channel
configuration).
1. Use the change ds1 UUCSS command to set the
Near-End CSU Type
field on the DS1 circuit pack administration form to integrated, and/or
change the
Bit Rate
field to “1.544” if the board is to be used in a
24-channel configuration.
2. Retry test ds1-loop UUCSS ds1/csu-loopback-tests.
1015
ABORT
Ports on the DS1 Interface circuit pack have not been busied out to
out-of-service.
1. Enter the busyout board UUCSS command to put all trunks or ports of the
DS1 Interface circuit pack into the out-of-service state.
2. Retry the command.
1039
ABORT
The DS1 Interface circuit pack is providing timing for the system. Executing
this test could cause major system disruption.
If the DS1 Interface circuit pack needs to be tested, set the synchronization
reference to another DS1 Interface circuit pack or to the Tone-Clock circuit via
the following command sequence:
1. Issue the disable synchronization-switch command.
2. Next, issue the set synchronization UUCSS command.
3. Lastly, issue the enable synchronization-switch command.
1950
ABORT
Another loop-back/span test is already executing on the DS1 board or the
board is in a network requested loop-back mode (Line loop back or Payload
loop back). The hardware error log indicates whether a Customer Loopback
Jack test, Far CSU Loopback test, or the One-Way Span test is executing or if
the board is in line loop-back or payload loop-back mode. Only one
long-duration loop-back/span test can be active at a given time. Thus, if a
loop-back/span test is already active, that test must be deactivated via the test
ds1-loop UUCSS end-loopback/span-test command in order to execute this
test.
1951
ABORT
The CSU Repeater Loopback test could not be executed because the 120A
CSU module
/T1 sync splitter
was not physically installed. Physically connect
the 120A1 CSU module
/T1 sync splitter
to the TN767E board behind the port
carrier.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...