![Avaya S8700 Series Скачать руководство пользователя страница 1554](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021554.webp)
Maintenance-Object Repair Procedures
555-233-143
8-832
Issue 1 May 2002
Notes:
a. The fiber is in frame, but no communication exists to the neighbor.
b. This is the normal state for an active PN EI circuit pack that is also the bus
master (expansion Archangel) in the PN.
c. This is the normal state for an active EI circuit pack that is not the bus
master (expansion Archangel) for an PN. This applies only in the direct
connect configuration where the EI circuit pack in an PN connects via a
fiber link to an EI circuit pack in the other PN. This state also applies for an
active EI circuit pack located in the PN.
d. This is the normal state for a standby expansion Interface circuit pack in
the PN.
For more details about how the EI circuit pack error codes relate to the LED
states, see
‘‘EXP-INTF (Expansion Interface Circuit Pack)’’ on page 8-762
Notes:
a. A Fiber is out of frame or a fiber loss-of-signal condition exists.
b. DS1 CONV/fiber endpoint communication is down.
c. The DS1 channel is down between the two DS1 CONVs in the DS1
converter complex.
Table 8-317.
Expansion Interface Circuit Pack Amber LED Flashing Codes
Condition
LED on
LED off
Fiber Out-of-Frame
0.1 second
0.1 second
(a) In frame-No Neighbor
0.5 second
0.5 second
(b) Expansion Interface Active
2 second
0.2 second
(c) Expansion Interface Active
Solid on
Never off
(d) Expansion Interface Standby
Never on
Solid off
Table 8-318.
DS1 CONV Amber LED Flashing Codes
Condition
LED on
LED off
(a) Fiber out of Frame
0.1 second
0.1 second
(b) In frame, fiber channel is down
0.5 second
0.5 second
(c) In frame, DS1 channel down
1 second
1 second
(d) DS1 CONV no response from media
server
2 second
0.2 second
DS1 CONV active
Solid on
Never off
DS1 CONV standby
Never on
Solid off
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...