M/T-ANL (Maintenance/Test Analog Port)
Issue 1 May 2002
8-1153
555-233-143
7
FAIL
Conference test failed on the primary information channel.
1. Run the circuit pack tests to check the Tone-Clock (TONE-BD) circuit pack
and the Tone Detector circuit pack via the test board UUCSS command.
2. Resolve any problems that are detected on the Tone-Clock (TONE-BD)
circuit pack or Tone Detector circuit pack. See the section on Tone
Generator circuit pack.
3. If the Tone-Clock and Tone Detector circuit packs are functioning properly,
and the test still fails, replace the Maintenance/Test circuit pack.
14
FAIL
The primary information channel is not transmitting properly. User may not
notice any interruption in service or may not be able to use this port.
1. Run the circuit pack tests to check the Tone Generator circuit pack and the
Tone Detector circuit pack using test board UUCSS.
2. Resolve any problems that are detected on the Tone Generator circuit pack
or Tone Detector circuit pack. See the section on Tone Generator circuit
pack.
3. If the Tone Generator and Tone Detector circuit packs are functioning
properly, and the test still fails, replace the Maintenance/Test circuit pack.
PASS
The Maintenance/Test analog port analog trunk testing capability is operating
correctly.
Table 8-473.
Test #13 Analog Port Digital Loop-Around Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...