Maintenance Commands
555-233-143
7-130
Issue 1 May 2002
2002
IP URJ-Build UCF
msg
Unregistration Request rejected:
failure to build an unregistration
request confirm (UCF) message
(internal software error).
0
IP address
2003
IP URJ-PSA
unmerge failed
Unregistration Request rejected:
PSA unmerge operation failed
(internal software error).
UID
IP address
2004
IP URJ-No stn user
record
Unregistration Request rejected:
PSA unmerge operation failed
(internal software error).
UID
IP address
2005
IP URJ-PSA
unmerge failed
Unregistration Request rejected:
PSA unmerge operation failed
(internal software error).
UID
IP address
2006
IP FURQ-no H.323
ext reg
Force Unregistration Request.
Received a KeepAlive RRQ from
a dual-connect endpoint without a
registered H.323 extension
(cannot make calls). Re-register
the endpoint.
UID
IP address
2007
IP FURQ-User, no
sig conn
Force Unregistration Request.
Unregister user because there is
no signaling connection. RAS is
alive, but the signaling connection
has gone down (user cannot make
calls). Re-register the endpoint.
UID
IP address
2008
IP FURQ-H323, no
sig conn
Force Unregistration Request.
Unregister associated H.323 user
because there is no signaling
connection. Re-register the
endpoint.
UID
IP address
2009
IP FURQ-Move user
Force Unregistration Request.
Extension is already registered,
but received a force login RRQ.
Send a URQ to the existing
extension.
UID
IP address
2010
IP FURQ-Restart
cleanup
Force Unregistration Request.
Instruct the RAS manager to
cleanup a UID that had just been
registered prior to a system
restart.
UID
0
Table 7-16.
Denied IP events —
Continued
Event
Type
Event Description
Explanation
Event
Data 1
Event
Data 2
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...