Maintenance-Object Repair Procedures
555-233-143
8-494
Issue 1 May 2002
Audit Update Test (#36)
This audit verifies that the hardware state of the data line is consistent with the
system translations. The audit queries the port for the switchhook state, the
software state is updated according to the returned value. Also, the audit data line
options down to the port.
Digital Loop-Around Test (#171)
The Digital Looparound test checks the data line port’s ability to transmit and
receive data on the TDM Bus. Data is sent through an available
Maintenance/Test digital port over the TDM Bus, internally looped through the
data line port back onto the TDM Bus, and received again by the same
Maintenance/Test digital port.
Note that only one of the two digital ports on a Maintenance/Test circuit pack is
used for this test, and that port must be the first such port; such as port 02. If
port 02 is in use, out-of-service, or not present, the test aborts. This test may fail if
the Maintenance/Test digital port used by the test is not functioning properly. If
there are any M/T-DIG errors in the Error Log, see
clear them first. This test will pass regardless of any customer
equipment that may be connected to the port, as long as the equipment is not
using the port.
Table 8-200.
Test #36 Audit Update Test
Error
Code
Test
Result
Description / Recommendation
1000
ABORT
System resources required to run this test are not available.
1. Retry the command at 1-minute intervals up to 5 times.
2. Escalate the problem if the test continues to abort.
1006
ABORT
An existing Error Type #769 on this port prevented the test from running.
1. Follow the procedure following the Error Log Table for Error Type #769.
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
ABORT
Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
7
FAIL
Internal system error
1. Try the command again at 1-minute intervals up to 5 times.
PASS
The hardware port state is consistent with the software state. Investigate
user-reported troubles on this port using other port tests and examining the
ADU, external wiring, and customer equipment.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...