![Avaya S8700 Series Скачать руководство пользователя страница 1989](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271021989.webp)
PKT-INT (Packet Interface)
Issue 1 May 2002
8-1267
555-233-143
Reset Test (#889)
The reset action initializes the Packet Interface firmware on the IPSI circuit pack
and runs a comprehensive set of diagnostic tests.
The demand reset action will abort if the specified IPSI circuit pack’s Packet
Interface is in the active in-service state.
An IPSI circuit pack’s Packet Interface is put in the out-of-service state
automatically if it has been reset 3 times by background maintenance within the
last 15 minutes, independent of the results of the reset action.
If this is a high- or critical-reliability system and if the Packet Interface is on the
standby IPSI, the demand reset action will run, independent of the service state.
2000
ABORT
Response to the test request was not received within the allowable time period.
1. Retry the command at 1-minute intervals up to 3 times.
2500
ABORT
Internal system error
1. Retry the command.
NO
BOARD
The IPSI circuit pack’s Packet Interface circuit is assigned, but is not detected
as being physically present.
1. If the IPSI circuit pack is present, replace it.
2. If not, insert a TN2312AP IPSI circuit pack in the assigned slot, and rerun
the test.
1
FAIL
Setting up peer links between the active and standby IPSI circuit pack’s Packet
Interface circuits failed.
1. Use the display alarms command to display active alarms.
2. If errors related to the packet bus exist, see
to clear those problems first.
3. Retry the test command after a 1-minute delay.
4. If the test continues to fail, replace the standby IPSI circuit pack.
Table 8-513.
Test #888
Active-Standby Peer Link Test
—
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...