Maintenance-Object Repair Procedures
555-233-143
8-1090
Issue 1 May 2002
Error Log Entries and Test to Clear Values
Notes:
a. The data link between the port and the terminal is not operational (i.e., the
port circuitry has detected an off-board problem). Verify that the MET set is
connected and that the EPF (Electronic Power Feed) test passes. If data
transmission problems are experienced, check for defective wiring or a
defective voice terminal, or move terminal electrically closer to the switch
(i.e., reduce the length of the wiring between the terminal and the switch).
If the problem persists, replace the circuit pack. Once the problem is
resolved, the system retires the alarm after a predetermined time delay.
Table 8-447.
MET Line Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm Level
On/Off
Board
Test to Clear Value
0
1
1.
Run the short test sequence first. If every test passes, run the long test sequence. Refer to each appropriate
test’s description, and follow its recommended procedures.
0
Any
Any
Any
test port UUCSSpp sh r 1
1 (a)
40987
None
18 (b)
0
busyout port
UUCSSpp
WARNING
OFF
release port UUCSSpp
130 (c)
None
WARNING
ON
test port UUCSSpp sh
257 (d)
40988
None
MINOR
WARNING
2
2.
Major or Minor alarms MO may be downgraded to Warning alarms based on the values used in the set options
command.
OFF
513 (e)
40965
Hybrid Line Station
Audits test (#61)
WARNING
OFF
test port UUCSSpp sh r 4
769
Port Diagnostic test
(#35)
MINOR
WARNING
ON
test port UUCSSpp l r 3
1025
Hybrid and Conf.
Circuits test (#57)
MINOR
WARNING
ON
test port UUCSSpp l r 3
1537 (f)
40968
None
MINOR
WARNING
OFF
1793
TDM NPE Crosstalk
test (#6
MINOR
WARNING
ON
test port UUCSSpp l r 3
2049 (g)
32770
2049 (h)
40967
3840 (i)
40989
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...