H323-SGRP (323 Signaling Group)
Issue 1 May 2002
8-891
555-233-143
Notes:
a. Error Type 1 — Represents a failure of the C-LAN hardware carrying the
signaling group D channel. Check for errors against the CLAN-BD MO.
b. Error Type 257 — Tracks failures of the H.323 signaling-group PING test.
H.323 signaling-group PING test failures are documented later in this MO.
c. Error Type 513 — Tracks excessive round-trip delay of the H.323
signaling-group PING test (if the round-trip delay exceeds 4 seconds).
d. Error Type: 770 — Tracks excessive latency and packet-loss from
background IP measurements collected by the Media Processor Board.
e. Error Type 1025 — Indicates that the signaling group has been placed into
a BYPASS condition because of IP network congestion. The signaling
group accepts incoming calls, but every outgoing call is denied. The
system routes these calls over a secondary route, if one has been
administered.
f. Error Type 1281 — Implies that no medpro resources are in service to
provide media connections for the trunk members of the signaling group.
g. Error Type 1794 — The Sig Group reported that the far end has detected
excessive packet latency or loss.
h. Error Type 2049 — A Keep-Alive timer is set for every registered endpoint
on the Remote Office, and the switch expects Keep-Alive update within
that timer’s time period. If the update does not occur, a message is
generated that causes an error to be logged against MO REM-OFF, as well
as MO H323-SGRP. Because the signaling group is still known, the error
against MO H323-SGRP generates a Minor alarm. This error is only valid
if the change signaling group form has the
RRQ
field set to
y
. This error
counter is only set if a failure has been detected by Avaya MultiVantage ™
software and it notifies maintenance software. The Keep-Alive Error Type
2049 clears only after a registration occurs and Error Type 2305 clears.
i. Error Type 2305 — Indicates that the Gateway (signaling group on the
Remote Office) is unregistered. Because the signaling group is still known,
the error against MO H323-SGRP generates a Minor alarm when this
failure occurs. This error is only applicable if the change signaling group
form has the
RRQ
field set to
y
.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...