ATM-EI (Expansion Interface Circuit Pack)
Issue 1 May 2002
8-207
555-233-143
1033
ABORT
The test cannot run because either the ATM-EI board is not administered, or
there were no other PNs administered that had its ATM-EI board in-service.
1. Ensure that the board is administered as ATM PNC Expansion Interface
circuit pack.
2. If the board is administered as ATM-EI circuit pack, then there has been
some change in the ability of the ATM-EI circuit pack in the other PNs to
communicate with the ATM-EI on the other end of its connection.
3. Using status port x (the port-network number where the board is
administered), see if both ACL and EAL are up to this board. If not, see the
service procedure for SYS-LINK.
4. Check the Error Log for Error Type 1281 with Aux Data 27 (board cannot
talk to the ATM switch). See
for repair
procedures.
5. If present, check both the ATM switch and the MultiVantage translations for
consistent ATM addresses. Reset the board, and see if the problem
resolves.
6. Repeat Test #241. If it continues to abort with this abort code, replace the
board.
1394
ABORT
1. See
(Error Type 1281) with Aux Data 27 (board
cannot talk to the ATM switch), and if present, check both the ATM switch
and the MultiVantage translations for consistent ATM addresses.
2. Reset the board and see if the problem resolves.
3. Repeat the test.
1395
ABORT
This test cannot run on an ATM-EI circuit pack if it is part of the B-side PNC and
Duplicated PNC is not enabled.
1. If this test needs to run on this ATM-EI circuit pack, enable PNC with the
change system-parameters duplication command.
2. Prevent the system from doing a PNC interchange by executing the set
PNC lock command.
3. Repeat this test.
1413
ABORT
This test requires the use of a Tone-Clock circuit in each of the EPNs used in
this test. This abort code indicates that a Tone-Clock circuit is absent from one
of the EPNs.
1. Verify that an IPSI or Tone-Clock circuit pack resides in the same EPN as
the ATM PNC Expansion Interface circuit pack under test.
2. In ATM PNC configurations, make sure that there is at least one other EPN
besides the EPN where the ATM-EI circuit pack under test resides that
contains a Tone-Clock circuit.
Table 8-85.
Expansion Interface 2-Way Transmission Test (#241) —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...