UDS1-BD (UDS1 Interface Circuit Pack)
Issue 1 May 2002
8-1779
555-233-143
CSU Equipment Loop-Back Test (#1210)
This test is destructive.
The CSU Equipment Loopback (ELB) test causes a loopback at the near-edge of
the local 120A1 CSU module or the 401A T1 sync splitter and tests the connection
from the DS1 board to the CSU module/T1 sync splitter (DS1 board edge
interconnecting cable, and CSU module/T1 sync splitter edge). This test is only
performed if the 120A1 CSU module or the 401A T1 sync splitter is present,
administered, and connected to a 1.544-Mbps DS1 circuit pack behind the port
carrier.
The test is destructive and can only be initiated by a system technician demanded
test ds1-loop UUCSS ds1/csu-loopback-tests command.
Every trunk or port on the UDS1 Interface circuit pack must be busied out using
the system technician busyout board command before running the ELB test.
When the ELB test is initiated, maintenance software sends an appropriate
message to the UDS1 Interface circuit pack to start the test. The board sets up
the ELB loopback, transmits a test pattern, and verifies that the pattern is received
unaltered through the loopback. If the transmitted and received pattern is
different, the test fails.
When the test is complete, every trunk or port on the UDS1 Interface circuit pack
is restored to the in-service state after the release board command is entered.
Table 8-683.
Test #1210 CSU Equipment Loop-Back Test
Error
Code
Test
Result
Description / Recommendation
ABORT
Internal system error
1. Retry the test ds1-loop UUCSS ds1/csu-loopback-tests command at
1-minute intervals up to 5 times.
1005
ABORT
CSU Equipment Loopback test cannot be executed in the current configuration.
To run this test, the Near-End CSU Type field on the DS1circuit pack
administration form must be set to integrated and the “Bit Rate” field on the
DS1 circuit pack administration form must be set to “1.544” (24-channel
configuration).
1. Use the change ds1 UUCSS command to set the Near-End CSU Type
field on the DS1 circuit pack administration form to integrated, and/or
change the “Bit Rate” field to “1.544” if the board is to be used in
24-channel configuration.
2. Retry the test ds1-loop UUCSS ds1/csu-loopback-tests command.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...