ATM-TRK (Circuit Emulation Service Circuit Pack)
Issue 1 May 2002
8-297
555-233-143
ATM Board Time Of Day Update (#1261)
The nondestructive ATM-TOD-UPD test updates the system time used by the
ATM-TRK circuit pack for SDH/SONET performance monitoring and synchronizes
the ATM-TRK circuit pack with the S8700 Multi-Connect system’s clock. This test
is run during initialization, scheduled maintenance, and craft long test.
Table 8-130.
ATM Board Time Of Day Update (#1261)
Error
Code
Test
Result
Description / Recommendation
2031
FAIL
The attempt to send the message to the ATM-TRK circuit pack was not
successful.
2500
FAIL
Internal system error. Did not send the time-of-day information to the board.
1. Retry the command up to 3 times at 1-minute intervals.
2. If the test aborts with the same error code, escalate the problem.
PASS
The ATM-TRK circuit pack is successfully updated with system time.
1. If the status port-network command still indicates that this link is down, it
is possible that one or both of the ATM-TRK circuit packs have been
busied out.
2. If the link still does not come up, reset one or both ATM-TRK circuit packs
on the link.
0
NO
BOARD
No board detected.
1. Check the error log for wrong board (Error 125) or no board (Error 131).
Resolve either of these issues, if applicable.
2. Check that the board is properly translated and inserted. If so, check for
hyperactivity (Error 1538). If hyperactive, use the reset board UUCSS
command.
1. Run the test again. If it fails, the board could be bad. Replace the board
and retest.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...