DIG-LINE (Digital Line)
Issue 1 May 2002
8-547
555-233-143
m. Error Type 3840—with Aux Data 40965 No terminal is connected to the
Digital Line board. No maintenance action is required.
Error Type 3840—with Aux Data 40989 An uplink message has been
logged indicating that the Electric Power Feed (EPF) is on with no load on
it. No action is necessary.
n. Error Type 3841—The circuit pack’s message buffer is full. This may be
caused by having many display phones with heavy traffic connected to the
circuit pack. No action is necessary.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below. By clearing
error codes associated with the Voice and Control Channel Local Loop-around
test, for example, you may also clear errors generated from other tests in the
testing sequence.
Digital Terminal Remote Loop-around Test
(#1201)
This test checks the connection between the media server and the digital terminal
and the ability of the terminal and the associated port to send and receive data.
This test is based on procedure 622 to isolate digital terminal problems.
A request is presented to the terminal to go into loop-back mode. Data is sent to
the terminal and when received back, checked for consistency. This test is run as
a part of the test long procedure. It is not included in any error recovery strategy
and generates no error log entries or alarms. To begin the test, Maintenance will
ask Avaya MultiVantage ™ software to make the associated endpoint and port
Maintenance Busy. This test succeeds if the endpoint is “idle”. If the reserve
request fails then the test aborts. If the request succeeds then the media server
sends a message to loop around both information channels for the digital terminal.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
Digital Terminal Remote Loop-around test
(#1201)
X
D
Voice and Control Channel Local Loop-around
test (#13)
X
ND
Digital Line NPE Crosstalk test (#9)
X
ND
Digital Line Electronic Power Feed test (#11)
X
ND
DIG-LINE Station Lamp Updates test (#16)
X
X
ND
Station (Digital) Audits test (#17)
X
X
ND
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...