Maintenance-Object Repair Procedures
555-233-143
8-1004
Issue 1 May 2002
1114
ABORT
The signaling link is in a transitional state.
1. Retry the command at 1-minute intervals up to 5 times.
1116
ABORT
The trunk is not in the out-of-service/far-end state that is required to run this
test on systems using a country protocol other than 1.
1117
ABORT
A service state audit message is outstanding.
1. Wait 2 minutes and then try again.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1113
FAIL
The signaling link has failed; the system cannot send any messages on behalf
of this trunk.
1. Consult procedures for ISDN-SGR (ISDN-PRI Signaling Group) and
ISDN-LNK (ISDN Signaling Link Port).
FAIL
Internal system error
1. Retry the command at 1-minute intervals up to 5 times.
PASS
Wait 4 minutes and then check the Error Log for any new errors of type 3073. If
there are none, then both sides of the ISDN connection agree on the service
state; the negotiation succeeded. If there is a new 3073 error, then the
negotiation failed (the far-end switch twice failed to respond within 2 minutes).
The switch will automatically retry every 15 minutes. If the trunk was initially in
service, it is now placed in the maintenance/far-end state. Incoming calls will
be accepted, but no outgoing calls can be originated. If an incoming call is
presented, another Service State Audit will be immediately performed in an
attempt to put the DS1 ISDN Trunk in the proper state.
Table 8-398.
Test #256 Service State Audit Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...