c. Error Type 259—A log-only error indicating that the target board failed to
download. To resolve the error, use the command test firmware
download. The Aux Data specifies the error. See the table below for more
details.
6
Invalid suffix on the change firmware download screen does not match suffix
of image on the source board. Verify screen, make sure the correct image is
being used.
7
Source board absent, verify entry on the change firmware download screen
and translations.
8
Incorrect source board, verify that the source board is the correct TN code.
9
PPP ports not available, use another source board or reschedule the download
for off hours.
10
DL Setup message to source failed. Retry download and if download still fails
escalate.
Table 8-333.
Error Type 259 Aux Data
Aux
Data
Description of Failure
1
Target board absent / not responding, check board location, translations and retry.
2
Incorrect target board for download schedule, verify board location, and schedule.
3
Target failed to go into DL Mode, retry
4
Target received bad file header
5
Bad image checksum on image on source board, get new image retry.
6
TFTP protocol error - One reason for this type of failure could be that the target board
has ami-zcs line coding and resides in a PN with ami-zcs line coding between the source
and target board. To have a successful firmware download you must have a clear
channel between the source and target board. Some examples of the correct type of
line coding for this feature are: b8zs, and hdb3.
7
File transfer timer expired, check board location, translations and retry.
8
Target failed to reset after transfer, check board location, translations and retry.
10
Download of target failed, check location, translations, and retry.
13
The target board rejected the download image. Check translations, verify image file,
retry then escalate.
Continued on next page
Aux
Data
Description of Failure
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...