test alarms
Issue 1 May 2002
7-411
555-233-143
Parameters
auto-page
This option provides the ability to continue testing and displaying test
results, by providing a new screen every time the SAT screen is filled with
test results. The screen does not scroll to accommodate new results;
instead a new screen is provided after the current screen fills up.
If the auto-page option is not specified, the SAT screen will not be
refreshed once it is filled with test results and testing will stop until the user
enters the "PAGE" key to continue or the "CANCEL" key to halt the testing.
failures
This requests that only the failures be displayed on the screen. All passes
will not be displayed on the output screen. Hardware failures as well as
aborts, conflicts and PN-down failures will be displayed.
step
This option will allow the user to step to the next or previous alarm and not
have the current alarm tested. When this option is specified, the user is
presented with the alarm information and prompted for a keypress. The
user may enter CANCEL to abort the command, ENTER to test the
currently displayed alarm, NEXT ALARM (function key) to move to the next
alarm, PREV ALARM (function key) to move to the previous alarm without
testing the currently displayed alarm. If this option is given, then the NEXT
ALARM (function key) or PREV ALARM (function key) may be pressed at
any time during the command (even during test results). If the NEXT
ALARM or PREV ALARM is pressed during a test, the test is aborted,
testing of the current alarm stops, and the next alarm or previous alarm is
displayed. If the first alarms is displayed, and the PREV ALARM is
pressed, then the last alarm is displayed. Also, if the last alarm is currently
displayed, and the NEXT ALARM is requested, then the first alarm will be
shown.
NOTE:
When this option is given the only way to terminate this command is
to press CANCEL.
short
This will cause the command to execute a series of nondestructive
diagnostic tests.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...