Maintenance-Object Repair Procedures
555-233-143
8-1676
Issue 1 May 2002
3. If the t/c selector has not undergone an interchange since the error
occurred, go to the next step. If such an interchange has taken
place, interchange back to the formerly active t/c selector. Use the
set expansion-interface command when investigating an EPN
Tone-Clock.) If the interchange attempt fails due to other errors,
resolve those problems first.
4. Interchange the IPSI or Tone-Clock circuits, using the set
tone-clock PC command. If the command succeeds, the
interchange which previously failed has been accomplished and the
problem has been satisfactorily resolved. If it fails, proceed to the
next step. (You may want to proceed in any case to definitively test
all relevant components.)
5. Interchange the t/c selector using set expansion-interface if
investigating an EPN. If errors prevent this interchange, resolve
them first.
6. Attempt again to interchange Tone-Clocks with the set tone-clock
PC command.
If the Tone-Clock interchange failed for both t/c selectors, replace
the standby Tone-Clock circuit pack which could not be
interchanged into and return to this step. (See
.) Test the new circuit pack as follows:
a. Execute the set tone-clock PC command.
b. Execute set expansion-interface, if this is an EPN
Tone-Clock.
c. Execute the set tone-clock PC command again.
If these commands successfully complete, the problem has
been resolved.
— If these commands successfully complete, the
problem has been resolved.
— If the IPSI or Tone-Clock circuit packs successfully
interchange when one EXP-INTF is active, but not
when the other one is:
The t/c-selector circuit pack on the failing side is
suspect.
d. Replace the EXP-INTF board that is active when the
Tone-Clock interchange fails. (For the Expansion Interface,
see
‘‘EXP-INTF (Expansion Interface Circuit Pack)’’ on page
e. Make sure the new t/c selector is active and execute the set
tone-clock PC command.
— If both Tone-Clocks can be interchanged into, and
interchanges succeed when either t/c selector is
active, the problem has been resolved.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...