![Avaya S8700 Series Скачать руководство пользователя страница 813](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_3027102813.webp)
ANL-LINE, ANL-NE-L (8-Port Analog Line)
Issue 1 May 2002
8-91
555-233-143
2000
ABORT
Response to the test request was not received within the allowable time period.
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
1
FAIL
This does not indicate a hardware problem. The switchhook audit failed, and
the other updates were not performed because of this failure. This condition
may occur when the audit is performed at the same time that the terminal
equipment goes off-hook. Use the status station command to determine
when the port is available for testing.
1. When the port becomes available for testing, retry the command at
1-minute intervals up to 5 times.
5
FAIL
This does not indicate a hardware problem but may indicate an internal
software error. The message waiting lamp update failed. The translation and
ringer updates were not performed because of this failure.
7
FAIL
The translation update failed. The ringer update was not performed because of
this failure. This does not indicate a hardware problem but may be an internal
software error.
8
FAIL
This does not indicate a hardware problem but may be an internal software
error. The ringer update failed.
1. Retry the command at 1-minute intervals up to 5 times.
PASS
The software and the port processor have the same status. User-reported
troubles on this port should be investigated by using other port tests, by
examining station wiring, by examining the station, and by ensuring that the
terminal is correctly translated as off-premises or on-premises.
NOTE:
This test always passes for circuit packs TN712 prior to vintage 14 and
TN742 prior to vintage 6.
Table 8-36.
Test #36 Station Status and Translation
Audits and Updates Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...