Analog Tie Trunk Back-to-Back Testing
The TN760 circuit pack can be configured for back-to-back testing (also known as
connectivity testing) by making translation and cross-connect changes. This
testing configuration allows for the connection of tie trunks back-to-back in the
same switch to verify the operation of tie trunk ports. The tests can be performed
in either the E&M or simplex modes.
E&M Mode Test Procedure
1. At the administration terminal, enter list configuration trunks to
determine which ports are assigned on the Tie Trunk circuit pack.
2. Enter display dialplan command to determine the Trunk Access Code
(TAC) format.
3. Enter display port xxx for every port defined in
. This displays the
trunk groups of which the ports are members. For details about removing
and replacing port circuit packs, see
‘‘Reseating and Replacing Circuit
4. Insert the circuit pack back into the slot.
5. Enter display trunk xxx p for each trunk group identified in
command displays the specified trunk group on the administration terminal
screen and prints a hard copy on the printer. Save this data for later use.
6. Remove every member defined by these ports from the trunk group(s)
using the change trunk xxx command.
7. Remove the Tie Trunk circuit pack from the carrier slot.
8. Set the dip (option) switches for each of the two ports to be tested on the
Tie Trunk circuit pack to “E&M mode” and “unprotected.”
9. Enter add trunk n to add a new (test) trunk group. Then enter information
for the following fields:
10. Locate the tie trunk port terminal connections at the cross-connect field.
Consult the appropriate table below for either 110-type or 66-type
hardware.
Group Type
tie
TAC
Use trunk access code obtained from dial plan
Trunk Type (in/out)
wink/wink
Port
Assign two of the ports from the tie trunk.
Mode
E&M for both ports
Type
Specify one port as t1 standard and other port
as t1 compatible.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...