Maintenance-Object Repair Procedures
555-233-143
8-1678
Issue 1 May 2002
s. Error type 3999
Τ
his error type indicates that the circuit pack sent a
large number of control channel messages to the switch within a short
period of time. If error type 1538 is also present, then the circuit pack was
taken out of service due to hyperactivity. If error type 1538 is not present,
then the circuit pack has not been taken out of service, but it has generated
50% of the messages necessary to be considered hyperactive. This may
be completely normal during heavy traffic periods. However, if this error
type is logged when the circuit pack is being lightly used, it may indicate a
problem with the circuit pack or the equipment attached to it.
System Technician-Demanded Tests:
Descriptions and Error Codes
Always investigate tests in the order presented in the table below when inspecting
errors in the system. By clearing error codes associated with the SAKI Reset test
for example, you may also clear errors generated from other tests in the testing
sequence.
Order of Investigation
Short Test
Sequence
Long Test
Sequence
Reset Board
Sequence
D/ND
1
1.
D = Destructive; ND = Nondestructive
SAKI Reset test (#53) (a)
X
D
Clock Health test (#46)
X
X
ND
Control Channel Loop-Around test (#52) (a)
X
X
ND
Tone Generator Crosstalk test (#90) (b)
X
ND
Tone Generator Transmission test (#40) (b)
X
X
ND
Tone Generator Audit/Update test (#41) (b)
X
X
ND
Tone Detector Verification test (#42) (e)
X
X
ND
Tone Detector Audit/Update test (#43) (e)
X
X
ND
TDM Bus Clock Circuit Status Inquiry test
(#148) (c)
X
X
ND
TDM Bus Clock Slip Inquiry test (#149) (c, e)
X
X
ND
TDM Bus Clock PPM Inquiry test (#150) (c)
X
X
ND
TDM Bus Clock Parameter Update test
(#151) (c)
X
X
ND
Board Type Check test (#574) (c)
X
X
ND
Standby Reference Health Check test (#651)
(c, d)
X
ND
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...