Maintenance-Object Repair Procedures
555-233-143
8-1658
Issue 1 May 2002
TIME-DAY (Time of Day)
The time of day contains the current year, month, day of the week, day of the
month, hour, minute, and second. The Time of Day MO is responsible for
monitoring the time-of-day clock and raising an alarm if the time-of-day clock is
not set or cannot be read by the software. If the time-of-day clock is not set or
cannot be read by the software, many features such as Time-of-Day Routing,
CDR, ISDN Call-by-Call, duplication, and so on will be either inoperative or
incorrect. The time-of-day clock should be set using the set time command
whenever the system is initially powered up.
The time-of-day clock can be read with the display time command and set via the
set time command. The time-of-day clock has a backup battery to save the time
of day during power failures.
Error Log Entries and Test to Clear Values
To resolve the alarm, do the following:
1. Use the set time command to set the time of day.
2. Use the display time command to display the time of day. If the time of
day is displayed correctly, wait 15 minutes and verify that the alarm is
retired.
MO’s Name (in
Alarm Log)
Alarm
Level
Initial SAT Command
To Run
Full Name of MO
TIME-DAY
MINOR
set time
Time of Day
Table 8-645.
Time-of-Day Error Log Entries
Error
Type
Aux
Data
Associated Test
Alarm
Level
On/Off
Board
Test to Clear Value
0
0
Any
Any
Any
display time
247
1
1.
This error indicates that software cannot read the time-of-day clock. During this condition, every time stamp
in Alarm Log entries, Hardware Error Log entries, and Software Error Log entries is potentially inaccurate.
In addition, any features that are sensitive to the time of day (such as SMDR, Time-of-Day Routing, ISDN
Call-by-Call) will not function correctly.
0
none
MINOR
OFF
set time
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...