Maintenance-Object Repair Procedures
555-233-143
8-1570
Issue 1 May 2002
CRC Error Counter Test (#623)
This test is nondestructive.
This test reads the BRI port’s CRC error counters that are maintained on the BRI
circuit pack. The Cyclic Redundancy Check (CRC) is a means of error detection
used to determine the integrity of data frame contents. The CRC error counter is
incremented by the circuit pack when it detects a CRC error. The test passes if
the value of the counter is 0 (that is, the error is cleared). If the counter is
non-zero, the test fails, and the value of the counter is displayed in the
Error
Code
field.
Receive FIFO Overflow Error
Counter Test (#625)
This test is nondestructive.
This test reads and clears the BRI port’s Receive FIFO Overflow error counter
maintained on the TBRI-BD circuit pack. This counter is incremented by the
circuit pack when it detects an overflow of its receive buffers. The test passes if
the value of the counter is 0 (that is, the error is cleared). If the counter is
non-zero, the test fails, and the value of the counter is displayed in the Error Code
field. This error can occur either if:
■
Signaling frames are being received from the Packet bus at a rate sufficient
to overflow the receive buffers on the circuit pack for a port
■
A hardware fault is causing the receive buffers not to be emptied properly
by the circuit pack.
This test is useful for verifying the repair of the problem.
Table 8-610.
Test #623 CRC Error Counter Test
Error
Code
Test
Result
Description / Recommendation
ANY
FAIL
This error occurs when a frame with a bad CRC is received over the D channel
by the BRI board. This error is reported on a per-port basis when the counter
goes over the threshold. This error is most likely due to a problem with the
wiring or interference on the wiring caused by a noise source or no termination.
It usually does not indicate a problem with the circuit pack.
PASS
The CRC error counter was read correctly and has a value of 0.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...