![Avaya S8700 Series Скачать руководство пользователя страница 2184](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022184.webp)
Maintenance-Object Repair Procedures
555-233-143
8-1462
Issue 1 May 2002
103
FAIL
The SNI circuit pack cannot communicate with the equipped SNI in slot 3.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 257, replace the SNI
being tested. Replacing an SNI may be service interrupting. See
(SNI Circuit Pack)’’ on page 8-1429
for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 257, replace the SNI in
slot 3. Replacing an SNI may be service interrupting. See
Circuit Pack)’’ on page 8-1429
for the procedure for replacing an SNI.
Retry the command.
104
FAIL
The SNI circuit pack cannot communicate with the equipped SNI in slot 4.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 513, replace the SNI
being tested. Replacing an SNI may be service interrupting. See
(SNI Circuit Pack)’’ on page 8-1429
for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 513, replace the SNI in
slot 4. Replacing an SNI may be service interrupting. See
Circuit Pack)’’ on page 8-1429
for the procedure for replacing an SNI.
Retry the command.
105
FAIL
The SNI circuit pack cannot communicate with the equipped SNI in slot 5.
1. Perform the Fiber Fault Isolation Procedure described in Chapter 5. This
will resolve multiple SNI-PEER errors.
2. If the SNI being tested has SNI-PEER error type 769, replace the SNI
being tested. Replacing an SNI may be service interrupting. See
(SNI Circuit Pack)’’ on page 8-1429
for the procedure for replacing an SNI.
To view SNI-PEER errors, use the display errors command with category
PNC-PEER. Retry the command.
3. If the SNI being tested has SNI-PEER error type 769, replace the SNI in
slot 5. Replacing an SNI may be service interrupting. See
Circuit Pack)’’ on page 8-1429
for the procedure for replacing an SNI.
Retry the command.
Table 8-579.
TEST #759 Configuration Audit —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...