Maintenance-Object Repair Procedures
555-233-143
8-360
Issue 1 May 2002
When this error occurs for an ASAI or Avaya adjunct, the service technician
should:
1. Execute the test station extension command and pay particular
attention to any tests that fail and perform the associated repair
procedures for those tests.
2. Check the health of the adjunct by following the recommended
repair procedures of the manufacturer of the adjunct if the preceding
step does not resolve the problem.
3. The alarm condition persists and, if the above steps do not resolve
the problem, follow normal escalation procedures.
d. This error and associated WARNING alarm are logged against an ASAI or
Avaya endpoint when the adjunct has asked the switch to suspend
Maintenance on the ASAI or Avaya endpoint. Busying out and releasing
the ASAI station or ADJLK station will clear this alarm.
e. This error occurs when the endpoint sends more messages than the switch
can handle. The switch suspends the reception of messages from the
endpoint for a short period of time. There is no repair procedure for this
error. If the condition persists, replace the endpoint.
f. This error occurs when a BRI endpoint’s signaling-associated link has too
much traffic related to link establishment. This could occur if the signaling
link is bouncing between assigned and established states. Software will
suspend activity to this endpoint for 75 minutes when the endpoint is
alarmed due to this problem (note that service suspension does not occur if
the endpoint is an ASAI or Avaya adjunct). If this problem persists, replace
the endpoint. If replacing the endpoint does not fix the problem, follow
normal escalation procedures.
g. This error occurs when the ASAI-ADJ or ATT-ADJ or LGATE-AJ or
ATTE-AJ message is not transmitted because the PKT-CTRL (Packet
Control circuit pack) transmit buffers are exhausted. Frequent or persistent
occurrence of these events may indicate a hardware problem or traffic
overload on the PKT-CTRL, the signaling link, or the ASAI or Avaya
adjunct. Attempt to resolve the problem by following the repair procedures
for the PKT-CTRL. If these attempts fail, the problem should be escalated
because re-engineering of the traffic on the PKT-CTRL, signaling link, or
adjunct may be necessary.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...