Maintenance-Object Repair Procedures
555-233-143
8-840
Issue 1 May 2002
1415
ABORT
The lightwave transceiver is absent from Endpoint 1 of the fiber link (list
fiber-link can be used to display fiber link endpoints).
1. If a lightwave transceiver should not be present, do nothing. For example,
an SNI connected to a DS1 CONV circuit pack or an SNI with a metallic
connection does not have a lightwave transceiver. This test can only be
run when a lightwave transceiver exists.
2. Otherwise, continue with the following steps.
3. Check the lightwave transceiver connections.
4. Replace the lightwave transceiver. If a fiber out-of-frame condition exists
and lightwave transceivers are used, check that the lightwave transceivers
are of the same type (both are 9823a or both are 9823b). If they are not
the same type, replace one of the lightwave transceivers.
5. Replace the SNI circuit pack.
1416
ABORT
The lightwave transceiver is absent from Endpoint 2 of the fiber link (list
fiber-link can be used to display fiber link endpoints).
1. If a lightwave transceiver should not be present, do nothing. For example,
an SNI connected to a DS1 CONV circuit pack or an SNI with a metallic
connection does not have a lightwave transceiver. This test can only be
run when a lightwave transceiver exists.
2. Check the lightwave transceiver connections.
3. Replace the lightwave transceiver. If a fiber out-of-frame condition exists
and lightwave transceivers are used, check that the lightwave transceivers
are of the same type (both are 9823a or both are 9823b). If they are not
the same type, replace one of the lightwave transceivers.
4. Replace the SNI circuit pack.
127
FAIL
The data is not correctly looped around on Endpoint 1 of the fiber link (list
fiber-link can be used to display fiber link endpoints).
1. Check the lightwave transceiver.
2. Replace the lightwave transceiver. If a fiber out-of-frame condition exists
and lightwave transceivers are used, check that the lightwave transceivers
are of the same type (both are 9823a or both are 9823b). If they are not
the same type, replace one of the lightwave transceivers.
3. Replace the SNI circuit pack.
Table 8-326.
Test #756 SNI Off-Board Destructive Facility Test —
Continued
Error
Code
Test
Result
Description / Recommendation
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...