![Avaya S8700 Series Скачать руководство пользователя страница 2294](http://html1.mh-extra.com/html/avaya/s8700-series/s8700-series_maintenance-manual_30271022294.webp)
Maintenance-Object Repair Procedures
555-233-143
8-1572
Issue 1 May 2002
The Deactivated state indicates a problem with the TBRI-BD circuit pack. When
in this state, the Level 1 interface is not active, and an idle signal is transmitted to
the channels or that Layer 1 was deactivated by the switch. When an TBRI-PT
port is placed in the out-of-service state, Level 1 is also put into the Deactivated
state. This could be due either to the system detecting a fault with the port or to a
busyout port UUCSSpp request.
Table 8-612.
Test #1242 Level 1 Status Inquiry
Error
Code
Test
Result
Description / Recommendation
1187
ABORT
The board or port may be busied out.
1. Look in the Error Log for Error Type 18 (port busied out) for this port and
TBRI-BD (board busied out). If this error type is present for TBRI-PT only,
then release the port with the release port pp command and run the test
again. If the error is present for both TBRI-BD and TBRI-PT, then release
the board with the release board UUCSS command and run the test
again.
NOTE:
When you release a board, you release every port associated with it. If
certain ports still need to be busied out, use the busyout port
UUCSSpp command to busy them out.
2. Make sure the endpoint is connected.
3. Retry the command at 1-minute intervals up to 5 times.
2000
ABORT
Response to the test was not received from the circuit pack within the allowable
time period.
1. If the test aborts repeatedly up to 5 times, reset the circuit pack with the
busyout board UUCSS, reset board UUCSS, and release board
UUCSS commands.
2. If the test aborts again, replace the circuit pack.
2012
ABORT
Internal system error
2100
ABORT
Could not allocate the necessary system resources to run this test.
1. Retry the command at 1-minute intervals up to 5 times.
Continued on next page
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...