monitor system
Issue 1 May 2002
7-223
555-233-143
These forms contain simplified high-level information from which a basic picture of
the system’s health can be drawn. The monitor system conn command displays
output that shows the status of connections in the connection manager process.
Data is collected frequently in the connection manager for certain key information
items. It is from this database that this report is drawn. This on-line status report
is automatically updated every minute (or by pressing the
UPDATE
key) until the
command is canceled by pressing the
CANCEL
key. Pressing the
CANCEL
keys
forces a logout of the current login ID.
There is one option to the command-line entry, monitor system conn. That
parameter is pnn. On the gaz target, there are only three possible pnns. On the
mips target, however, up to 22 pnn can be administered. The command-line
parameter pnn is used to indicate which three pnns the user wishes to see.
Defaults
No defaults.
Parameters
Error Messages
If the pnn number entered is non numeric, not administered, or invalid in any other
way, one of following messages will be displayed:
Object command word omitted; please press HELP
“xx” is an invalid identifier; press RETURN to execute
modified command
If during the execution of a command a resource problem occurs that requires the
user to restart the command, then the following message will be displayed:
Command resources busy; Press CANCEL to clear, and then
resubmit
view1
This specifies a form that will include the attendant status, the maintenance
status, the last hour’s measurement of trunk groups, hunt groups, and the
attendant group, and finally, the time of day.
view2
This specifies a form that will display a subset of the view1 form entries. This
form will include all of the view1 form except the last hour’s hunt group
measurements.
conn
This option will bring up the connection monitor output for key information.
entering no
options
Omitting the “pnn # # #” argument on the command line will cause the default
configuration of Pnn’s 1, 2 and 3 to be displayed.
pnn # # #
Entering “pnn # # #”, where “#” is replaced by a pnn number from 1 to 3, will
cause data for the specified pnns to be displayed.
Содержание S8700 Series
Страница 50: ...Maintenance Architecture 555 233 143 1 26 Issue 1 May 2002 ...
Страница 74: ...Initialization and Recovery 555 233 143 3 12 Issue 1 May 2002 ...
Страница 186: ...Alarms Errors and Troubleshooting 555 233 143 4 112 Issue 1 May 2002 ...
Страница 232: ...Additional Maintenance Procedures 555 233 143 5 46 Issue 1 May 2002 ...
Страница 635: ...status psa Issue 1 May 2002 7 379 555 233 143 status psa See status tti on page 7 406 ...
Страница 722: ...Maintenance Commands 555 233 143 7 466 Issue 1 May 2002 ...
Страница 1121: ...CARR POW Carrier Power Supply Issue 1 May 2002 8 399 555 233 143 Figure 8 19 Power Distribution Unit J58890CH 1 ...
Страница 1447: ...E DIG RES TN800 reserve slot Issue 1 May 2002 8 725 555 233 143 E DIG RES TN800 reserve slot See ASAI RES ...
Страница 1735: ...LGATE AJ Issue 1 May 2002 8 1013 555 233 143 LGATE AJ See BRI SET LGATE BD See BRI BD LGATE PT See BRI PT ...
Страница 1846: ...Maintenance Object Repair Procedures 555 233 143 8 1124 Issue 1 May 2002 Figure 8 62 TN787 MMI MULTIMEDIA INTERFACE CIRCUIT PACK ...