User Manual for 4 Port Modbus RTU/ASCII to Modbus TCP Gateway, SC10E4M K &SC10E4IM K 

 

Introduction 

SC10E4M K 4-Ports Modbus RTU/ASCII To Modbus TCP Gateway providing new ways of connecting 
serial devices to a Wireless LAN (Wi-Fi 802.11 b/g/n ). This Gateway is designed to operate 4 serial 
ports through wireless (Wi-Fi 802.11 b/g/n) over 10/100Mbps Ethernet network. As the data is 
transmitted via TCP/IP protocol, data acquisition and controlling is available to go through Intranet and 
Internet. 4 Serial ports operate in common RS-232, RS-422 and RS-485 auto selection modes 
configuration. 
 
SC10E4M K is embedded with MT7688AN MIPS chipset makes it become the ideal device for 
transmitting the data from your RS-232 or RS-422/485 Serial interface devices, such as PLCs, various 
Meters and/or Sensors to an IP-based Wi-Fi LAN, and making it possible for your software to access 
Serial interface devices anywhere and anytime. 
 
SC10E4IM K provides Modbus TCP Server and Modbus TCP Client Mode for selection. It supports 
manual configuration via web browser and support various protocols including TCP, IP, HTTP, DHCP, 
ICMP and ARP. These are the best solution to coordinate your Serial interface devices. 
 

Product Specifications

 

System 

 

CPU 

 

 

: MT7688AN MIPS CPU, 580 MHz 

 

RAM   

 

: 128M Bytes DDR2 RAM   

 

ROM   

 

: 32M Bytes Flash ROM   

 

OS 

 

 

: Open Wrt Linux OS   

 

Support 8 TCP Master each 32 simultaneous request or 8 TCP Slave on each RTU port. 

Ethernet 

  Port Type 

 

: RJ-45 Connector 

  Speed   

 

: 10 /100 M bps (Auto Detecting) 

  Protocol 

 

: ARP, IP, ICMP, UDP, TCP, HTTP, DHCP 

  Protocol 

 

: NTP, FTP 

  Mode   

 

: Modbus TCP Server and Client, Modbus RTU Master and Slave 

  Setup   

 

: HTTP Browser Setup (IE & Netscape), Console 

  Security  

 

: Setup Password 

  Protection 

 

: Built-in 1.5KV Magnetic Isolation 

WiFi port 

 

Standard   

: 2.4G IEEE 802.11b/g/n 

 

Data Rate   

: 11/54/72.2 Mbps @ 20Mhz Band Width 

 

Modulation   

: DSSS; OFDM 

 

Frequency   

: 2.4GHz 

 

Tx Power 11b 

: Max. 22dBm 

 

Tx Power 11g/n  : Max. 19dBm 

 

Rx Sensitivity 

: -76dBm @ 54Mbps, -89.5dBm @ 11Mbps 

 

Tx Rate 

 

: Max. 54Mbps with auto fallback 

 

Tx Distance  

: Up to 100m 

 

Security 

 

: WEP 64-bit / 128-bit data encryption, WPA / WPA2 personal 

 

Antenna 

 

: 2 dBi, RP-SMA connector 

 

Network Mode  : Infrastructure; Soft AP (for Setup) 

 

Mode   

 

: TCP Server / TCP Client / Serial Master / Serial Slave 

 

Setup  

 

: HTTP Browser Setup (IE, Chrome, Firefox) 

 

Security 

 

: Login Password 

 

Содержание SC10E4IM K

Страница 1: ...es Modbus TCP Server and Modbus TCP Client Mode for selection It supports manual configuration via web browser and support various protocols including TCP IP HTTP DHCP ICMP and ARP These are the best solution to coordinate your Serial interface devices Product Specifications System CPU MT7688AN MIPS CPU 580 MHz RAM 128M Bytes DDR2 RAM ROM 32M Bytes Flash ROM OS Open Wrt Linux OS Support 8 TCP Mast...

Страница 2: ...din rail extension Weight 660 gm WARRANTY 1 year Product Panel Views Antenna Connector The connector for antenna is a standard reverse SMA jack Simply connect it to a 2 0dBi dipole antenna Standard Rubber Duck and it is 50 Ohms impedance and can support 2 4GHz frequency Ethernet Port The connector for network is the usual RJ45 Simply connect it to your network switch or Hub When the connection is ...

Страница 3: ...y inoperable When the power is on and the SYS LED light on use a point tip to press this button and hold it and wait for more than 25 seconds All the parameters will be reset to the factory default LED Indicators PWR Red After power on this LED is always On SYS Green After power on and system working this LED start blinking Wi Fi Red LED is ON after power on then off a while It starts blinking aft...

Страница 4: ... to setup the IP Address To proceed with the parameters setup please use a web browser IE or Chrome to continue Configuration When setting up your Gateway for the first time the first thing you should do is to configure the IP address IP Search Utility Setup 1 Copy SC10E4IMK Utility from CD ROM or our Web site to your host computer 2 SC10E4IMK is a self extract install program Double click it to i...

Страница 5: ...Pune 411045 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Click on Find button It will scan the network and show up the IP of Gateway Ethernet IP Address 192 168 1 100 Wi Fi IP Address 10 0 0 1 ...

Страница 6: ...ding email info santelequip com Click Setup button will pop up a window You may change Name Description IP Netmask of device Click Setup to save setup The device s IP must be same subnet with host PC NB enable to use web browser open configuration page Click Goto button will open a web page of configuration default ID admin password admin ...

Страница 7: ...069393 Connecting Converting Leading email info santelequip com Now you have successfully connected to the Gateway Configuration There are 4 setup pages as System Network Serial and Gateway System Setup System where you can change Password set up Auto Reset time and modify Device Name Description of device ...

Страница 8: ...045 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Appearance of Wireless Ethernet setup NTP Enable Disable NTP function Set up NTP server and Time Zone Firmware update Click Browse to open file manager ...

Страница 9: ...rting Leading email info santelequip com Click to select the file with specified version and click Confirm button When the selected file name appears on the input column click Update button Setup is successfully configured Please click Save and go to other pages for configuration or click Save and Restart to run new configuration ...

Страница 10: ...ne 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Network setup Wireless section Type to select INFRASTRUCTURE or ACCESS POINT When selected INFRASTRUCTURE go to SSID click Scan will get list of available SSID select one to link ...

Страница 11: ...word and select mode DHCP or STATIC In LAPTOP PC choose same SSID to link When selected ACCESS POINT Gateway acts as an Access Point which is allowed to be connected by PC NB Smart Phone PAD It supports DHCP server function Soft AP broadcasts its SSID SANXX_XX_XX_XX_XX_XX PC NB Smart Phone PAD should connect to this SSID and then open web browser with default IP for Gateway setup ...

Страница 12: ...ghts Baner Road Pune 411045 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Password Key in selected AP log in password Encrypt Mode STATIC To input assigned IP address Subnet Mask ...

Страница 13: ...9393 Connecting Converting Leading email info santelequip com Ethernet select STATIC or DHCP to assign IP address Gateway and DNS To check with MIS for right IP address Setup is successfully configured Please click Save and go to other pages for configuration or click Save and Restart to run new configuration ...

Страница 14: ...se clearly set each parameters from Serial 1 to Serial 4 default 19200 n 8 1 Baud Rate 300 bps to 921 6K bps Parity None Even Odd Data Bits 5 6 7 8 Stop Bits 1 2 Flow Control None XON XOFF RxDelay ms 0 TxDelay ms 0 Setup is successfully configured Please click Save and go to other pages for configuration or click Save and Restart to run new configuration Gateway Setup There are Modbus Gateway 1 2 ...

Страница 15: ...504 505 Deron Heights Baner Road Pune 411045 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com Four Modes are selectable Please select Gateway type as per your setup ...

Страница 16: ...tem sends query to RTU Slave device then RTU Slave device response back to TCP Master s requirement Inside the Modbus gateway there are TCP Slave RTU Master counterparts respectively 2 TCP to ASCII Slave TCP Master Device ex Modscan SCADA system sends query to ASCII Slave device then ASCII Slave device response back to TCP Master s requirement Inside the Modbus gateway there are TCP Slave ASCII Ma...

Страница 17: ...ce then TCP Slave device response back to RTU Master s requirement Inside the Modbus gateway there are TCP Master RTU Slave counterparts respectively Set up to 8 slaves on each port 4 ASCII to TCP Slave ASCII Master Device ex PLC Modscan sends query to TCP Slave device then TCP Slave device response back to ASCII Master s requirement Inside the Modbus gateway there are TCP Master ASCII Slave count...

Страница 18: ...etup is successfully configured Please click Save and go to other pages for configuration or click Save and Restart to run new configuration After configued all parameters click Save and Restart to reboot system Support 8 TCP Master Reset button if needed Ensure power is on press Reset button for over 20 seconds then release SC10E4IM K will set configuration back to default ...

Страница 19: ...San Telequip P Ltd 504 505 Deron Heights Baner Road Pune 411045 India Phone 91 20 27273455 9764027070 8390069393 Connecting Converting Leading email info santelequip com ...

Отзывы: