background image

ProBridge Gateway

User Manual

Содержание ProBridge

Страница 1: ...ProBridge Gateway User Manual ...

Страница 2: ...sons is entirely coincidental Trademarks and patents GE and the GE monogram are registered trademarks of General Electric Other trade names used in this document may be trademarks or registered trademarks of the manufacturers or vendors of the respective products Intended use Use this product only for the purpose it was designed for refer to the data sheet and user documentation For the latest pro...

Страница 3: ...n Environment 6 1 2 POWER 6 1 3 PROBRIDGE GATEWAY PRODUCT DIAGRAM 7 1 3 1 Dipswitch Position Legend 8 2 PROGRAMMING MODE 8 3 OPERATING MODE 9 4 OPERATION 10 4 1 ADDRESSING 10 4 2 PRESETS 10 5 CABLE SPECIFICATIONS 10 5 1 PROBRIDGE TO DVMRE TRIPLEX CABLE 10 5 2 PROBRIDGE TO PC CABLE 11 5 3 PROBRIDGE TO I O JUNCTION BOX OR CYBERDOMES11 6 SPECIFICATIONS 12 ...

Страница 4: ... hookups Read these instructions and all ancillary documentation entirely before installing or operating this product The most current versions of this and related documentation may be found on our website Note A qualified service person complying with all applicable codes should perform all required hardware installation These terms may appear in this manual WARNING Improper use of this equipment...

Страница 5: ...pped to dome address number 983 In the Operating mode the ProBridge Gateway will translate messages to ensure that telemetry messages originating from DVMRe products will correctly address the intended dome 1 1 PROBRIDGE GATEWAY COMPONENTS The ProBridge Gateway product includes 1 CBR PB3 GW ProBridge unit 1 P N 4310 0034B RJ45 to RJ45 cable Connects the ProBridge Gateway RS485 Port 0 to the DVMRe ...

Страница 6: ...mitations Cable length between the PC and ProBridge is limited to 50 If the supplied cable is replaced by custom made cables to address distances between components ensure the cable is manufactured to ANSI standards for RS 232 communication RS485 Limitations If multiple RS485 devices are connected together the distance between the first and last device is limited to 3 000 feet RS 485 communication...

Страница 7: ...Supply Power Supply Input Voltage 220 Volt AC Tolerance 10 Frequency 50 Hz Power Supply Output Voltage 12 Volt DC Current 110mA Power 1 3 Watts Connector 2 1mm female barrel Center Positive 1 3 PROBRIDGE GATEWAY PRODUCT DIAGRAM Note Port 0 and Port 1 have looping RJ45 connectors ...

Страница 8: ...f Ensure the RS232 4310 0047B cable is connected from the PC to one of the port 1 connectors on the ProBridge Gateway Open HyperTerminal on a PC o Set the RS232 port to 9600 N 8 1 and flow control to None File Properties Connect to tab Configure button o Set local echo on File Properties Settings tab ASCII Setup button Cycle power on the ProBridge Gateway box and follow the instructions in HyperTe...

Страница 9: ...g mode Set the device to operating mode by setting the dipswitch at SW4 SW4 7 RS232 SEL off SW4 8 RS485 SEL on Connect the devices and cables as shown below Cycle power on the ProBridge Gateway box and the other devices Connection Diagram for Operating mode is shown below KB3 Protocol menu item must be set to YES ...

Страница 10: ...The DVMRe will receive these preset messages via TCP IP and convert them to RS485 5 CABLE SPECIFICATIONS 5 1 PROBRIDGE TO DVMRE TRIPLEX CABLE Part Number 4310 0034B Communication Type RS485 Connector Type RJ 45 RJ 45 Cable Required 5 Foot RJ 45 to RJ 45 Triplex RS485 Cable Supplied Connects ProBridge to DVMRe CT RJ 45 RJ 45 Connector Connector Pin 8 Brown Pin 7 Brown White Pin 6 Green Pin 5 Blue W...

Страница 11: ...perTerminal Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1 RJ 45 Connector DB 9F Connector Pin 8 Pin 7 Pin 6 Pin 5 Pin 4 Pin 3 Pin 2 Pin 1 Pin 9 RJ 45 Connector DB9F Connector 5 3 PROBRIDGE TO I O JUNCTION BOX OR CYBERDOMES Part Number 4310 0032A Communication Type RS485 Connector Type RJ45 Flying Leads Cable Required RS 485 Flying Leads Cable Interconnects ProBridge with KTD 405 and Dome Cameras...

Страница 12: ... Environmental Temperature 0 to 40 C operating Relative Humidity 90 non condensing Electrical AC Power External AC power supply included Voltage Range 110 to 240 VAC 10 Current 200 mA DC Power DC jack positive center Power Supply Voltage 12 VDC Current 110 mA Power 1 5 W Note All specifications are subject to change without notice GE believes that all specifications are correct however no liabilit...

Страница 13: ...he library go to our website at the following location http www gesecurity com In the Customer Support menu select the Publication Library link After you register and log on you may search through our online library for the documentation you need 1 Table 1 Sales and support contact information Sales Technical support Phone Toll free 888 GESECURity 888 437 3287 in the US including Alaska and Hawaii...

Страница 14: ......

Страница 15: ......

Страница 16: ......

Отзывы: