5. Basic Management Commands
42
Example
To display the console port setting:
5.13. config serial_port
Description
This command is used to configure the serial bit rate that will be used to communicate
with the management host and the auto logout time for idle connections.
Format
config serial_port {baud_rate [9600 | 19200 | 38400 | 9600] | auto_logout [never |
2_minutes | 5_minutes | 10_minutes | 15_minutes]}(1)
Parameters
Zxxx0:admin#show serial_port
Command: show serial_port
Baud Rate : 9600
Data Bits : 8
Parity Bits : None
Stop Bits : 1
Auto-Logout : 10 mins
Zxxx0:admin#
baud_rate
Specify the baud rate value. The default baud rate is 9600.
9600 Specify a baud rate of 9600.
19200
Specify a baud rate of 19200.
38400
Specify a baud rate of 38400.
115200
Specify a baud rate of 115200.
auto_logout
Specify the timeout value. The default timeout is 10_minutes.
never Specify to never timeout.
2_minutes
Specify when the idle value is over 2 minutes, the device will auto logout.
5_minutes
Specify when the idle value is over 5 minutes, the device will auto logout.
10_minutes
Specify when the idle value is over 10 minutes, the device will auto logout.
15_minutes
Specify when the idle value is over 15 minutes, the device will auto logout.
Summary of Contents for ZEQUO 6400
Page 160: ...12 Basic IP Commands 161 ...
Page 189: ...17 Command Logging Command List 190 ...
Page 554: ...49 MAC based Access Control Commands 555 ...
Page 812: ...69 QoS Commands 813 ...
Page 839: ...73 SNMPv1 v2 v3 Commands 840 Only Administrator level users can issue this command ...
Page 962: ...85 Virtual Router Redundancy Protocol VRRP Command List 963 ...
Page 1050: ...91 System Log Lists 1051 ...