63. PIM for IPv6 Command List
730
63.5. config pim6 crp
Description
This command is used to configure the PIM6 C-RP related parameters.
Format
config pim6 crp [rp <ipif_name 12> | all] {priority <value 0-255> | interval <sec 1-
16383>}(1)
Parameters
Restrictions
Only Administrator, Operator and Power-User level users can issue this command.
Example
To set the C-RP priority and the interval on the interface "System":
Zxxx0:admin#show pim6 cbsr
Command: show pim6 cbsr
PIM6 Candidate-BSR Information
--------------------------------------
C-BSR Interface Name : System
C-BSR Priority : 64
C-BSR Hash Mask Len : 126
Zxxx0:admin#
ipif
Specify to apply the configurations to this specific IP interface.
<ipif_name 12>
Enter the IP interface name.
all
Specify to apply the configurations to all IP interfaces.
priority Specify for RP election.
<value 0-255>
Enter the value between 0 and 255. The lower the value is, the higher the priority is. The
default value is 192.
interval Specify the C-RP advertisement interval in seconds.
<sec 1-16383>
Enter the interval between 1 and 16383 seconds. The default value is 60.
Summary of Contents for ZEQUO 6400