67. Precision Time Protocol (PTP) Commands
771
67.8. config ptp boundary ports
Description
This command is used to configure the attributes of the PTP boundary clock. The
configuration takes effect when the PTP device is a boundary type.
Format
config ptp boundary ports [<portlist> | all] {announce [interval <sec 1-16> | timeout
<value 2-10>] | sync_interval [half_second | <sec 1-2>] | delay_req_interval <value 0-5>
| pdelay_req_interval <sec 1-32> | delay_mechanism [e2e | p2p]}(1)
Parameters
ports
Specifies the list of port used for this configuration.
<portlist>
Enter the list of port used for this configuration here.
all
Specifies that all the ports will be used for this configuration.
announce
(Optional) Specifies that the announce options will be configured.
interval
Specifies the mean time interval between successive announce messages. In line
with the IEEE 1588 protocol, the value of the announce interval is represented as
the logarithm to the base 2 of this time measured in seconds. If the input is not
allowed, then the input is automatically adjusted to allow the bigger and closest
value. The value of the announce interval should be uniform throughout a domain.
If the announce interval of one port changes, the announce interval of all the ports
must be changed automatically to be consistent.
<sec 1-16>
Enter the interval value used here. This value must be between 1 and 16
seconds.
timeout
Specifies the announce interval number that has to pass without receiving an
Announce message before the occurrence of the
ANNOUNCE_RECEIPT_TIMEOUT_EXPIRES event. This value multiplied by the
announce interval value is equal to the interval time of the announce receipt
timeout. The value of the interval time of the announce receipt timeout should be
uniform throughout a domain. If the value of one port is changed, the value of all
ports must be changed automatically to be consistent.
<value 2-10>
Enter the timeout value used here. This value must be between 2 and 10
seconds.
sync_interval
(Optional) Specifies the mean time interval between successive Sync messages.
half_second
Specifies that the syncronization interval will be set to half a second.
<sec 1-2>
Enter the syncronization interval value used here. This value must be between 1
and 2.
Summary of Contents for ZEQUO 6400
Page 160: ...12 Basic IP Commands 161 ...
Page 189: ...17 Command Logging Command List 190 ...
Page 554: ...49 MAC based Access Control Commands 555 ...
Page 812: ...69 QoS Commands 813 ...
Page 839: ...73 SNMPv1 v2 v3 Commands 840 Only Administrator level users can issue this command ...
Page 962: ...85 Virtual Router Redundancy Protocol VRRP Command List 963 ...
Page 1050: ...91 System Log Lists 1051 ...