background image

VER.  007_22.08.2011

LAN  REMOTE  SWITCH  GRL-­01  

MANUAL  INSTRUCTION

The  device  is  designed  for  
single-­phase  

installation  

and   must   be   installed   in  
accordance   with   standards  
valid  in  a  particular  country.  
The   device   should   be   con-­
nected  according  to  the  de-­
tails  included  in  this  operat-­

ing  manual.  Installation,  connection  and  control  

VKRXOGEHFDUULHGRXWE\DTXDOL¿HGHOHFWULFLDQ

staff,   who   act   in   accordance   with   the   service  
manual  and  the  device  functions.  
In  case  of  casing  dismantling  an  electric  shock  
may  occur,  and  the  guarantee  is  lost  then.  Be-­
fore    installation  make  sure  the  connection  ca-­
bles  are  not  under  voltage.  The  cruciform  head  
screwdriver  3,5  mm  should  be  used  to  instal  the  
device.  Improper  transport,  storage,  and  use  of  

WKHGHYLFHLQÀXHQFHLWVZURQJIXQFWLRQLQJ,WLV

not  advisable  to  instal  the  device  in  the  following  
cases:    if  any  device  part  is  missing  or  the  device  
is  damaged  or  deformed.  In  case  of    improper  
functioning  of  the  device  contact  the  producer.

CAUTION!

APPEARANCE

FEATURES

TECHNICAL  DATA

DESCRIPTION

Ɣ UHPRWH FRQWURO RI HOHFWULF GHYLFH RSH

ration   by   means   of   computer   network  
commands  -­  by  means  of  web  browser,

Ɣ FRPIRUWDEOHFRQWURORIGHYLFHVZLWKGLI¿

cult  access  (ventilation,  heating,  other),

Ɣ WKUHH RSHUDWLRQ PRGHV VZLWFKLQJ RQ

switching  off,  restart  -­  contact  relay  po-­
sition  change  for  adjusted  time),

Ɣ SRVVLEOH FRRSHUDWLRQ ZLWK VWDQGDUG QH

twork  devices  (routers,  switches,  etc.)

Ɣ 66/SURWRFROVHFXUHVFRQQHFWLRQ
Ɣ HDV\PRXQWLQJLQ9$&VRFNHW

Remote  switch  LAN  is  used  to  control  

lighting,  heating,  etc.  by  means  of  ether-­
net  (web  browser).  The  switch  is  mounted  
in  a  230  V~  socket  and  it  has  a  possibility  
of   a   remote   restart   (relay   status   change  
at  the  adjusted  time)  of  the  connected  de-­
vice,   which   is   done   by   means   of   a   safe  
SSL  protocol.

GRL-­01

Input  rated  voltage: 230  V~

Input  voltage  tolerance: -­15  ÷  +10  %

Nominal  power  consumption: 2  W

Optic  signalling  of  input  (supply): LED  green  diode

Number  of  operation  modes: 3

Accepted  communication  protocols: IP,  TCP,  UDP,  HTTP,  HTTPS,  DHCP,  ARP

Coding:   SSL  code  connection

Connection  parameters  (Link):   10  Mbps  /  Full  Duplex

LAN  socket  type: RJ  45

Optic  signalling  of  relay  status: LED  red  diode

Output  contacts  parameters: 1NO  16A  /  250V~  AC1  4000  VA  

Ambient  temperature  range: -­10  ÷  +55  

o

C

Operating  position: free

Casing  mounting: 230  V~    socket

Casing  protection  degree: IP20  (EN  60529)

Protection  level: II

Overvoltage  category: II

Pollution  degree: 2

Surge  voltage: 1  kV  (EN  61000-­4-­5)

Dimensions: 160  x  66  x  90  mm

Weight: 0,170  kg

Reference  standard: EN  60950-­1:2007,  

EN  55024:2000,  
EN  610004-­4

The  symbol  means  selective  

collecting  of  electrical  and  

electronic  equipment.    

It  is  forbidden  to  put  the  used  

equipment  together  with  other  

waste.

Optic  signalling  of  receiver’s  switch  on

Relay  manual  control

LAN  (RJ  45)  socket

Receiver’s  slot

Power  supply  plug

Optic  signalling  of  input  voltage

ZAMEL  

Sp.  z  o.o.

ul.  Zielona  27,  43-­200  Pszczyna,  Poland

tel.  +48  (32)  210  46  65,  fax  +48  (32)  210  80  04

www.zamelcet.com

,  e-­mail:  [email protected]

Reviews: