Version
Description
9.2(1.0)
Introduced on the Z9500.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
7.6.1.0
Introduced on the S-Series.
7.5.1.0
Introduced on the C-Series.
6.1.1.0
Introduced on the E-Series.
rmon hc-alarm
Set an alarm on any MIB object.
Z9500
Syntax
rmon hc-alarm
number
variable
interval
{delta | absolute}
rising-threshold value
event-number
falling-threshold
value
event-number
[owner
string
]
To disable the alarm, use the
no rmon hc-alarm
number
command.
Parameters
number
Enter the alarm integer number from 1 to 65535. The value
must be unique in the RMON alarm table.
variable
The MIB object to monitor. The variable must be in the
SNMP OID format; for example, 1.3.6.1.2.1.1.3 The object
type must be a 64-bit integer.
interval
Time, in seconds, the alarm monitors the MIB variables; this
is the alarmSampleType in the RMON alarm table. The range
is from 5 to 3600 seconds.
delta
Enter the keyword
delta
to test the change between MIB
variables. This is the alarmSampleType in the RMON alarm
table.
absolute
Enter the keyword
absolute
to test each MIB variable
directly. This is the alarmSampleType in the RMON alarm
table.
rising-
threshold
value
event-number
Enter the keywords
rising-threshold
then the value (64
bit) the rising-threshold alarm is either triggered or reset.
Then enter the event-number to trigger when the rising
threshold exceeds its limit. This value is the same as the
alarmRisingEventIndex or alarmTable of the RMON MIB. If
1566
Remote Monitoring (RMON)