Quick Start Guide PROFINET Switch 4/8-port

Version

2

en

www.helmholz.de

Summary of Contents for PROFINET 4-port

Page 1: ...ck Start Guide PROFINET Switch 4 8 port Version 2en www helmholz de Quick Start Guide PROFINET Switch 4 8 port Version Quick Start Guide PROFINET Switch 4 8 port Quick Start Guide PROFINET Switch 4 8 port ...

Page 2: ... detection 7 6 Assign the PROFINET switch a name 8 7 Media Redundancy Protocol MRP 9 8 Diagnosis and configuration via the web interface 10 9 Switch diagnosis and settings 12 10 Port mirroring 12 11 Statistics 13 12 Agents 14 13 SNMP 15 14 Setting the time 16 15 Resetting to factory settings 17 16 Firmware update 17 17 LED status information 18 18 Button functions 18 19 Technical data 19 ...

Page 3: ...ded from the website www helmholz de in the download area This document should explain the initial commissioning of the PROFINET switch for use in a PROFINET project FCN Function button RST Reset button P1 P4 For PROFINET devices or other Ethernet devices Voltage supply Operation LEDs see page 18 FCN Function button RST Reset button Voltage supply Operation LEDs see page 18 P1 P8 For PROFINET devi...

Page 4: ...our PROFINET network 2 Preparing the PROFINET switch 2 1 Connection The PROFINET switch must be supplied with 24 V DC at the wide range input 18 30 V DC via the provided connector plug The terminal FG is for the functional ground Connect this correctly with the reference potential The RJ45 sockets P1 P4 4 port switch and P1 P8 8 port switch are for the connection of the network 2 2 Install GSDML f...

Page 5: ... calling up the object properties you can assign the PROFINET switch a unique PROFINET name and check the IP address for plausibility in the project Important The real device must later be assigned the same name as in the project See also Chapter 6 ...

Page 6: ...uthorized infiltration of the network is prevented Automatic settings The port synchronizes itself automatically with the communication partner auto negotiation Automatic settings monitor The port synchronizes itself automatically with the communication partner auto negotiation A diagnosis alarm is triggered in the event of an absent Ethernet cable TP 100 Mbps Fixed specification of the transmissi...

Page 7: ...etect the topology of a PROFINET network or to specify it for purposes of checking for the correct structuring by the configuration If the topology was prescribed in the configuration neighboring devices can also be assigned the PROFINET name in the event of the replacement of a device The exchange of a device in operation is thus possible without the use of commis sioning tools ...

Page 8: ...ction Process Ethernet participant is used in the SIMATIC manager With the Browse button the network can be browsed for PROFINET participants The clear identification of the PROFINET switch is ensured here by the MAC address of the device Important The assigned name must agree with the name defined in the hardware configurator See Chapter 3 pages 4 5 If the PROFINET switch has been assigned the co...

Page 9: ...ll other participants of the ring are then MRP clients Helmholz TB20 C PROFINET IO Helmholz TB20 C PROFINET IO CPU PROFINET Switch I O System I O System Operator Panel MRP Ring Engineering Station X1 P4 X1 P1 X1 P2 X1 P3 Ext V DC 18 30 V FE IN1 IN2 PROFINET Switch 4 Port managed FCN RST PWR RUN BF SF MAC 00 00 00 00 00 00 In order to assign the PROFINET switch to an MRP ring the MRP domain must be...

Page 10: ...also accessible under the IP address assigned to the PROFINET switch in the PROFINET network When the web interface is first called up the password of the admin user is admin as of firmware V1 02 the password is the serial number of the device It is absolutely necessary to assign a new password following the first login ...

Page 11: ...ry of the new password Note If the PROFINET switch is configured and used in a PROFINET network settings in the web interface are only to be viewed as a diagnosis Non configured settings acquired from PROFINET Port Status LLDP DCP Ring Redundancy are then not possible in the web interface ...

Page 12: ...ort Mirroring can be activated in the PROFINET switch With Port Mirroring the frame transfer from one port via another port is completely mirrored on which an analysis PC can then record everything 9 Switch diagnosis and settings Extensive information and settings for the function of the switch are accessible in the Switch menu ...

Page 13: ...OFINET Switch 4 8 port 13 11 Statistics Detailed statistics on the data transfer can be queried in the Statistics menu Among other things the quality of the transmission can be monitored in the sub menu Statistics by Error ...

Page 14: ...agnosis and configuration via TELNET and SSH These accesses can be explicitly shut off for safety reasons You can find more information about the use of TELNET and SSH accesses in the manual In order to already be able to view basic information about the switch at the start website before you have logged in the option System Status Without Login can be selected ...

Page 15: ...t Guide PROFINET Switch 4 8 port 15 13 SNMP The PROFINET switch supports SNMP Simple Network Management Protocol in order to also enable the identification and diagnosis of the switch for IT administration tools ...

Page 16: ...rt Guide PROFINET Switch 4 8 port 16 14 Setting the time The PROFINET switch contains a system clock for the issuing of logs and alarm messages This can be set either manually or automatically by an SNTP server ...

Page 17: ...arameters and settings is acknowledged during the boot process by the SF LED lighting up 16 Firmware update A firmware update can be carried out via the web interface You are provided with the firmware update file by Helmholz Support or in the download area of the PROFINET switch under www helmholz de The firmware update file can be selected in the menu System Firmware The file has the ending HUF ...

Page 18: ...ote The LEDs RUN BF and SF all flash synchronously when the PROFINET function for device identification has been activated 18 Button functions FCN The PROFINET switch can be reset to factory settings with the FCN button If the FCN button is pressed during the run up time of the switch the orange SF LED begins to flash The blinking indicates that the switch will be immediately reset to factory sett...

Page 19: ...ing topology detection LLDP DCP Media Redundancy Protocol MRP Automatic addressing topology detection LLDP DCP Status indicator 4 LEDs function status 8 LEDs Ethernet status 4 LEDs function status 16 LEDs Ethernet status Voltage supply DC 24 V 18 30 V DC DC 24 V 18 30 V DC Current draw Max 250 mA with DC 24 V Max 350 mA with DC 24 V Permissible ambient temperature 40 C 75 C 40 C 65 C Transport and...

Page 20: ...e licensing conditions We will send you the appropriate licensing conditions including a copy of the complete licensing text together with the product These are also available in our download area of the respective product under www helmholz de We also offer to send you or any third party the complete source code of the applicable open source software as a DVD upon request for a contribution towar...