brief
(OPTIONAL) Enter the keyword
brief
to display the RMON
Ethernet history table in an easy-to-read format
Defaults
none
Command
Modes
EXEC
Command
History
This guide is platform-specific. For command information about other platforms,
refer to the relevant
Dell Networking OS Command Line Reference Guide
.
The following is a list of the Dell Networking OS version history for this command.
Version
Description
9.2(1.0)
Introduced on the Z9500.
8.3.19.0
Introduced on the S4820T.
8.3.11.1
Introduced on the Z9000.
8.3.7.0
Introduced on the S4810.
7.6.1.0
Introduced on the S-Series.
7.5.1.0
Introduced on the C-Series.
6.1.1.0
Introduced on the E-Series.
Example
(Index)
Dell#show rmon history 6001
RMON history control entry 6001
interface: ifIndex.100974631 TenGigabitEthernet 2/0
bucket requested: 1
bucket granted: 1
sampling interval: 5 sec
owner: 1
status: OK
Dell#
Example (Brief)
Dell#show rmon history brief
index ifIndex interface
---------------------------------------
6001 100974631 TenGigabitEthernet 1/0
6002 100974631 TenGigabitEthernet 1/0
6003 101236775 TenGigabitEthernet 1/1
6004 101236775 TenGigabitEthernet 1/1
9001 134529054 TenGigabitEthernet 2/0
9002 134529054 TenGigabitEthernet 2/0
9003 134791198 TenGigabitEthernet 2/1
9004 134791198 TenGigabitEthernet 2/1
Dell#
Remote Monitoring (RMON)
1573